Cable Leader 4 ft C20 to C13 14 AWG 15A 250V Green Computer Power Cord
- Green
- 41" - 4 ft.
We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Cable Leader
Red 14 AWG SJT extension adds 7 ft of reach between a C20 PDU or UPS and a C13 device, rated 15 A / 250 V and UL listed
This 7 ft red cord extends the reach between a PDU, UPS or server and an existing C13 cable. The male C20 plug connects to the power source and the female C13 socket accepts your current cord, so no adapter is required. Heavy duty 14 AWG copper with an SJT jacket handles 15 A at 250 V for server and data-centre loads.
The red jacket helps trace circuits and phases at a glance in dense racks. UL Listed and CSA certified (file E210037) with RoHS compliance gives documented safety assurance. It is not for installers who need a different connector pairing or a higher ampacity than 15 A.
The 14 AWG conductor and 15 A / 250 V rating determine whether the cord can carry the load of your equipment. If your gear draws more than 15 A you need a larger gauge; if it draws less the cord still works safely.
| Brand | GENERIC |
|---|---|
| Color | Red |
| Length | 5 - 10 ft. |
| Connector Number | 2 |
| Wire Gauge | 14 AWG |
Other versions of this model
Same family, different memory, cooler or clock — compare before you commit.
Insert the male C20 plug fully into the PDU or UPS outlet until the latch clicks; route the SJT jacket so the cable hangs straight down rather than bending sharply at the connector.
Replace it if the red SJT jacket shows cracks, the C13 socket grips loosely, or the grounding pin is bent — any visible damage means the 15A 250V rating can no longer be trusted.
The 14 AWG copper conductors are rated for 15A at 250V; sustained loads above 15A will trip the upstream breaker before the cable itself overheats.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
Same shelf, same checkout — eight coins and a 30-minute rate lock.
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?