We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Cable Leader

Cable Leader 5ft C20 to C19 12 AWG 20A 250V Blue

SKU CH-KMF8-PRWF0

A 5 ft heavy-duty 12 AWG extension cord with C20 male to C19 female connectors, rated 20A/250V and UL Listed for rack PDU and server power links

  • ColorBlue
  • Length5 - 10 ft.
  • Connector Number2
  • Wire Gauge12 AWG

Length 5ft

Color Blue

  • Extends C20/C19 power runs with a male C20 plug and female C19 socket
  • Heavy-duty 12 AWG copper carries 20 A at 250 V with a 105 °C SJT jacket
  • IEC 60320 connectors fit standard rack PDUs, UPS units and servers
  • Blue jacket enables quick circuit and phase identification in dense racks
  • UL Listed and CSA certified (file E210037) with RoHS compliance

Power Extension for Rack and PDU Gear

This 5-foot cord adds reach between a C20 outlet on a PDU or UPS and a C19 plug on a server or switch. It uses 12 AWG copper conductors rated for 20A at 250V under a grounded SJT jacket. The blue sheath helps identify circuits in dense rack installations. UL and CSA certifications confirm the safety rating for data-centre use.

Suits High-Current Rack Links.

Builders wiring 20A server or networking hardware in a rack will match the gauge and connector pair. Technicians who colour-code phases by cable jacket gain a visual trace aid. Installations limited to 10A or 13A loads do not need this conductor size; a lighter gauge reduces cost and bulk for those circuits. Environments requiring a different connector keying or voltage class must select another cable type.

12 AWG 20A Rating Decides Fit

The 12 AWG, 20-ampere rating is the single figure that determines whether this cord matches the branch circuit and equipment draw. If the protected circuit and the attached gear both specify 20A at 250V, this extension maintains the full rating without derating. Any circuit or device limited to a lower ampacity should use a correspondingly lighter cord instead.

Highlights

  • Extends C20/C19 power runs with a male C20 plug and female C19 socket
  • Heavy-duty 12 AWG copper carries 20 A at 250 V with a 105 °C SJT jacket
  • IEC 60320 connectors fit standard rack PDUs, UPS units and servers
  • Blue jacket enables quick circuit and phase identification in dense racks
  • UL Listed and CSA certified (file E210037) with RoHS compliance

Specifications

BrandGENERIC
ColorBlue
Length5 - 10 ft.
Connector Number2
Wire Gauge12 AWG

Other versions of this model

5 more in the same range

Same family, different memory, cooler or clock — compare before you commit.

Questions about this item

How much clearance does the C20 plug and C19 socket need behind a rack PDU?

The IEC 60320 C20 male plug and C19 female socket are standard rack-mount sizes; allow roughly 50 mm depth for the connector bodies plus cable bend radius.

What is the correct orientation when seating the C20 plug into a PDU and the C19 connector into this cord?

Align the keyed ground pin on the C20 plug with the PDU recess and push straight in until it clicks; then insert the existing C19 cord into the female end the same way — forcing either connector sideways bends the pins.

When should this 12 AWG SJT cord be inspected or replaced in a 20A server rack circuit?

Check the blue jacket for cracks, discoloration or heat marks at each end every 12 months; replace immediately if the 105 °C rated insulation shows stiffness or the UL Listed file E210037 label becomes illegible.

New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.