Unique-Bargains 44C2 DC 0-3A Class 1.5 Vertical Panel Current Meter Analog Ammeter electrician tool
DC 0–3 A analog panel ammeter with Class 1.5 accuracy and fine-tune adjustment
- Class 1.5 accuracy ensures reliable DC current readings
- 0-3A measuring range suits diverse electrical testing needs
- Clear scale with fine-tuning dial enables precise adjustments
- Compact 100 x 80 x 12mm panel fits tight installations
- Lightweight 127g design simplifies portable electrician work
Purpose and Audience
The Unique-Bargains 44C2 is a vertical panel analog ammeter designed for DC current measurement up to 3A with Class 1.5 accuracy. It serves electricians, technicians and hobbyists who need a clear, direct-reading instrument for electronics, automatic control systems, mechanical equipment, shipbuilding and aviation applications.
Thermals Noise and Power
As a passive analog meter the 44C2 draws negligible power from the measured circuit and produces no audible noise or measurable heat during normal operation. The movement relies on the current itself so there is no external supply requirement and no thermal load added to the panel or enclosure.
Build Quality and Connectivity
The unit weighs 127g and fits a 100 by 80 by 12mm panel cutout with a clear and black scale face. A rear zero-adjust button allows fine tuning of the needle without removing the meter. Two rear terminals accept standard ring or fork lugs for secure wiring in vibration-prone environments such as marine or industrial panels.
Highlights
- Class 1.5 accuracy ensures reliable DC current readings
- 0-3A measuring range suits diverse electrical testing needs
- Clear scale with fine-tuning dial enables precise adjustments
- Compact 100 x 80 x 12mm panel fits tight installations
- Lightweight 127g design simplifies portable electrician work
Specifications
| Brand | Unique Bargains |
|---|
Questions about this item
How do I mount and wire the 44C2 panel meter into a 100 x 80 mm cut-out?
Cut a 100 x 80 mm opening, slide the 12 mm thick case through from the front, secure the supplied brackets from behind, then connect the measured circuit in series with the two rear terminals.
What part of the 44C2 will need checking or replacement after extended use?
The taut-band movement and calibration spring can drift; verify accuracy against a reference source periodically and replace the meter if readings fall outside the Class 1.5 tolerance.
What limit appears first when the 44C2 runs continuously at 3 A?
The Class 1.5 accuracy envelope defines the first observable limit; sustained full-scale current keeps the pointer at the edge of its permitted error band.