Turck
Turck NI60-K90SR-FZ3X2 13429 Inductive Sensor 60mm
Rectangular inductive sensor with a 60 mm switching distance, programmable NC/NO output, and a PBT-GF30-V0 housing measuring 130 x 75 x 60 mm
- TypeTest Equipment
- Item Count1 pack
- Selling UnitBox
- Parts3 Years
- Labor1 Year
- 60 mm switching distance detects metal reliably
- Programmable NC/NO output adapts to control logic
- Wide 10–300 VDC and 20–250 VAC supply range
- Durable PBT-GF30-V0 housing resists industrial environments
- Terminal chamber simplifies wiring and maintenance
60 mm inductive sensor
The Turck NI60-K90SR-FZ3X2 is a rectangular inductive sensor with a 60 mm rated switching distance. It operates on AC 20…250 VDC or DC 10…300 VDC with a programmable NC/NO output. The housing uses PBT-GF30-V0 plastic and measures 130 x 75 x 60 mm with a terminal chamber connection.
Non-flush mounting requirement
This sensor suits applications needing a 60 mm sensing range on AC or DC supplies where programmable switching logic is required. It is not for flush-mount installations or for circuits that demand a specific DC-only or AC-only voltage band outside the stated ranges.
Terminal chamber connection
Electrical connection is made through a terminal chamber inside the rectangular housing. This screw-terminal interface determines whether the unit fits your existing wiring layout without adapters.
Highlights
- 60 mm switching distance detects metal reliably
- Programmable NC/NO output adapts to control logic
- Wide 10–300 VDC and 20–250 VAC supply range
- Durable PBT-GF30-V0 housing resists industrial environments
- Terminal chamber simplifies wiring and maintenance
Specifications
| Brand | TURCK |
|---|---|
| Model | NI60-K90SR-FZ3X2 13429 |
| Type | Test Equipment |
| Item Count | 1 pack |
| Selling Unit | Box |
| Parts | 3 Years |
| Labor | 1 Year |
Questions about this item
Will the NI60-K90SR-FZ3X2 13429 fit alongside my existing 130 x 75 mm rectangular sensors on the same mounting plate?
Yes, it shares the same 130 x 75 x 60 mm K90SR housing, so mounting hole centres and overall footprint match existing K90SR units.
What indication shows the NI60-K90SR-FZ3X2 13429 is switching correctly after installation?
The NC/NO programmable output changes state when a metal target enters the 60 mm sensing zone; watch the connected PLC input or indicator light toggle.
Does the NI60-K90SR-FZ3X2 13429 come with a mating cable, or must I supply one separately?
The sensor has a built-in terminal chamber for direct wiring; no pre-wired cable or connector is included in the box.