Turck
Turck NI4-M12E-AD4X-H1141 4406702 M12 inductive sensor 10-65 VDC NO 2-wire 30g
M12 inductive sensor detects metal at 4 mm range, runs on 10–65 VDC with a 2‑wire NO output and M12 connector, weighing 30 g
- TypeTest Equipment
- Item Count1 pack
- Selling UnitBox
- Parts3 Years
- Labor1 Year
- M12 threaded barrel fits standard mounting holes
- 10–65 VDC range suits varied power supplies
- Chrome-plated brass housing resists corrosion
- Non-flush mounting allows flexible installation
- 2-wire NO contact simplifies wiring
M12 inductive sensor for DC circuits
The Turck NI4-M12E-AD4X-H1141 is a non-flush mount inductive sensor built for DC control systems. Its chrome-plated brass barrel and M12 × 1 male connector suit industrial environments where reliable presence detection is required.
Thermals noise and power draw
The two-wire output operates across a 10…65 VDC supply range with a normally open contact function. Solid-state switching eliminates moving parts, so the device runs silently and draws only the load current needed by the connected circuit.
Build integration details
A threaded M12 × 1 barrel allows direct mounting into standard tapped holes without a separate bracket. The metal housing and connector share the same thread size, simplifying cable routing and reducing the number of adapter parts a panel builder must stock.
Highlights
- M12 threaded barrel fits standard mounting holes
- 10–65 VDC range suits varied power supplies
- Chrome-plated brass housing resists corrosion
- Non-flush mounting allows flexible installation
- 2-wire NO contact simplifies wiring
Specifications
| Brand | TURCK |
|---|---|
| Model | NI4-M12E-AD4X-H1141 4406702 |
| Type | Test Equipment |
| Item Count | 1 pack |
| Selling Unit | Box |
| Parts | 3 Years |
| Labor | 1 Year |
Questions about this item
How do I install the M12 × 1 threaded barrel and which step is often missed?
Screw the chrome-plated brass barrel into a non-flush mounting hole, then connect the M12 × 1 male connector. The step often missed is ensuring the non-flush mount clears the sensing face.
What maintenance or replacement will the sensor need later?
The sensor has no user-serviceable parts. Turck covers parts for three years and labour for one year; after that period a replacement unit is the only option.
What limit appears first under sustained use at the voltage extremes?
The 10…65 VDC operating window sets the limit. Continuous operation near 10 VDC or 65 VDC can push the output stage to its thermal boundary before any mechanical wear occurs.
Also in this aisle
People compared these