Turck
Turck Ni15-Q30-AP6X 4659325 Inductive sensor PNP electrician tool
A rectangular inductive proximity sensor with a 15 mm switching distance, PNP output and 10–30 VDC supply in a PBT housing
- TypeTest Equipment
- Item Count1 pack
- Selling UnitBox
- Parts3 Years
- Labor1 Year
- Detects metal at 15 mm rated distance
- Operates on 10 to 30 VDC supply
- PNP normally-open output simplifies wiring
- PBT-GF30-V0 housing resists harsh environments
- Compact 53 x 30 x 30.5 mm rectangular design
Industrial inductive sensor
The Turck Ni15-Q30-AP6X is a rectangular PNP inductive proximity switch designed for DC control circuits in automation and machine-building environments. Its non-flush mounting style and 15 mm rated switching distance suit presence detection of metal targets on conveyors, tooling fixtures or guarding systems.
DC three-wire operating limits
The sensor operates on a 10 to 30 VDC supply and provides a normally-open PNP output through a fixed cable connection. Voltage outside this range or loads that exceed the PNP stage’s current capability will cause unreliable switching or permanent damage to the output transistor.
Sensing range and mechanical headroom
The 15 mm rated distance delivers reliable detection of standard steel targets at close range while the PBT-GF30-V0 housing resists oils, coolants and mechanical impact in harsh industrial settings. Applications requiring longer stand-off, flush mounting or AC supply voltages fall outside this device’s specification.
Highlights
- Detects metal at 15 mm rated distance
- Operates on 10 to 30 VDC supply
- PNP normally-open output simplifies wiring
- PBT-GF30-V0 housing resists harsh environments
- Compact 53 x 30 x 30.5 mm rectangular design
Specifications
| Brand | TURCK |
|---|---|
| Model | Ni15-Q30-AP6X 4659325 |
| Type | Test Equipment |
| Item Count | 1 pack |
| Selling Unit | Box |
| Parts | 3 Years |
| Labor | 1 Year |
Questions about this item
Should I choose the 15 mm switching distance version or a shorter-range model?
The 15 mm rated switching distance suits applications needing longer non-flush detection; choose it when the target cannot be mounted close to the sensor face.
What does the 15 mm rated switching distance mean once the sensor is installed?
It detects a standard steel target at up to 15 mm from the active face; actual range varies with target material, size and mounting conditions.
The sensor uses a DC 3-wire 10…30 VDC interface — what does that cap in practice?
The 10…30 VDC supply range and PNP NO output work with typical PLC input modules; the cable connection limits maximum cable length to the voltage drop allowed by the 10 V minimum.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.