Turck
Turck BL67-8DI-PD 6827205 I/O module
Eight-channel digital input module with IP67 protection, wire-break monitoring and adjustable filters for fieldbus systems
- TypeTest Equipment
- Item Count1 pack
- Selling UnitBox
- Parts3 Years
- Labor1 Year
- 8 digital inputs capture signals reliably
- IP67 protection withstands harsh environments
- Galvanic isolation safeguards electronics from field disturbances
- Adjustable filter times adapt to application needs
- Wire-break monitoring detects cable faults early
Digital I/O module for fieldbus networks
The Turck BL67-8DI-PD is an IP67-rated electronic module that provides eight 24 VDC digital inputs with PNP switching. It connects via M8, M12 or M23 signal connectors and operates across a -40 °C to 70 °C temperature range. The unit weighs 55 g and carries order number 6827205.
Suited for distributed I/O.
This module suits engineers building modular, fieldbus-independent I/O stations that require channel diagnostics, wire-break monitoring and adjustable input filters. It does not serve applications needing analog signals, digital outputs or relay contacts. Buyers who need higher channel counts or different voltage levels should look elsewhere.
Eight 24 VDC inputs with galvanic isolation
The decisive specification is the eight galvanically isolated digital inputs, each monitored for wire-break and configurable for filter time and inversion. This input density and diagnostic depth determine whether the module fits the targeted machine or process design.
Highlights
- 8 digital inputs capture signals reliably
- IP67 protection withstands harsh environments
- Galvanic isolation safeguards electronics from field disturbances
- Adjustable filter times adapt to application needs
- Wire-break monitoring detects cable faults early
Specifications
| Brand | TURCK |
|---|---|
| Model | BL67-8DI-PD 6827205 |
| Type | Test Equipment |
| Item Count | 1 pack |
| Selling Unit | Box |
| Parts | 3 Years |
| Labor | 1 Year |
Questions about this item
Which fieldbus protocols does the BL67-8DI-PD support, and how does that affect wiring choices?
It runs on CANopen, DeviceNet, EtherNet/IP, Modbus TCP, PROFIBUS-DP, PROFINET or Ethernet, so the same module fits any of those networks without rewiring.
What mounting space and connection style does the module need?
The IP67-rated housing weighs 55 g and accepts M8, M12 or M23 signal connectors, letting it mount directly on the machine without a cabinet.
How are the eight 24 VDC PNP inputs configured, and what setting is often missed?
Each input offers wire-break monitoring, adjustable filter times and invertible logic; the filter time must be set per channel or noise will cause false triggers.