SQUARE D S29450 Auxiliary Switch for PowerPact H and J Circuit Breakers 6A
Auxiliary switch for PowerPact H and J circuit breakers, rated 6 A and compatible with frame sizes from 150 A to 3000 A, CSA certified, IEC, NEMA and UL listed
- Auxiliary switch adds remote status indication for PowerPact H and J breakers
- Rated 6 A for reliable signalling in control circuits
- Compatible with frame sizes 150, 250, 600, 800, 1200 and 3000 A
- Meets CSA, IEC, NEMA and UL standards for broad compliance
- Genuine Square D part S29450 ensures correct fit and function
Compatible Frame Sizes
The SQUARE D S29450 auxiliary switch fits PowerPact H and J circuit breakers across frame ratings of 150, 250, 600, 800, 1200 and 3000 amperes. It carries a 6 ampere contact rating for control circuits. The device is UL listed, CSA certified and meets IEC and NEMA standards.
Installers Adding Remote Indication
Electricians who need a dry contact to signal breaker position to a PLC, alarm panel or building management system will use this switch. It mounts inside the breaker accessory cavity without increasing the footprint. Buyers who require a higher contact ampacity or a different voltage class must select another accessory.
6 Ampere Contact Rating
The defining specification is the 6 A switching capacity on the auxiliary contacts. This value determines whether the switch can directly drive the coils, indicators or logic inputs in your control scheme. Verify that the load you intend to switch stays within this limit before specifying the part.
Highlights
- Auxiliary switch adds remote status indication for PowerPact H and J breakers
- Rated 6 A for reliable signalling in control circuits
- Compatible with frame sizes 150, 250, 600, 800, 1200 and 3000 A
- Meets CSA, IEC, NEMA and UL standards for broad compliance
- Genuine Square D part S29450 ensures correct fit and function
Specifications
| Brand | SQUARE D |
|---|
Questions about this item
How is the S29450 auxiliary switch installed on a PowerPact H or J circuit breaker, and what step is commonly missed?
Mount the switch inside the breaker accessory cavity and secure the terminal screws; the step often missed is verifying the breaker is fully de-energised before wiring the 6 A contacts.
What maintenance or replacement will the S29450 auxiliary switch need during its service life?
Periodically inspect the contact tips for erosion or carbon build-up and re-torque the terminal screws; replace the switch if contact resistance rises or the mechanism fails to toggle cleanly.
What is the first operational limit reached when the S29450 auxiliary switch is used continuously at its 6 A rating?
The 6 A contact rating is the primary limit; sustained current above 6 A will cause overheating and contact degradation before any frame-size constraint (150, 250, 600, 800, 1200, 3000 A) becomes relevant.