SQUARE D
SQUARE D QOB280 80A 2 Pole 120/240V AC circuit breaker
An 80 A two-pole breaker for 120/240 V AC panels with a 10 kA interrupt rating and bolt-on mounting
- 80 A two-pole protection for 120/240 V AC circuits
- 10 kA interrupting rating handles high fault currents
- Bolt-on mounting fits Square D QO and NQOD load centres
- 48 V DC rating adds low-voltage versatility
- Compact 3.5 × 1.5 × 2.9 in frame saves panel space
Application Fit
The Square D QOB280 is a bolt-on miniature circuit breaker rated at 80 A for single-phase 120/240 V AC panels. It suits electricians and facility managers who need standard over-current protection in Square D NQOD or QO load centres. Buyers needing a plug-on style, a three-pole device, or a higher AIR rating must select a different model.
Sustained Load Behaviour
The breaker carries its full 80 A rating continuously within a minimum operating temperature of 77 °F inside the enclosure. Thermal-magnetic trip characteristics respond to prolonged overloads without nuisance opening during normal motor-start currents. The 10 kA interrupting capacity at 120/240 V AC clears sustained fault currents safely.
Decisive Specification
The bolt-on mounting style and QOB series designation determine compatibility; the breaker only fits Square D NQOD panelboards that accept QO-frame bolt-on devices. Verify the panelboard series before purchase because plug-on QO breakers will not seat in this footprint.
Highlights
- 80 A two-pole protection for 120/240 V AC circuits
- 10 kA interrupting rating handles high fault currents
- Bolt-on mounting fits Square D QO and NQOD load centres
- 48 V DC rating adds low-voltage versatility
- Compact 3.5 × 1.5 × 2.9 in frame saves panel space
Specifications
| Brand | SQUARE D |
|---|
Questions about this item
How much heat does the 80 A breaker produce when it runs continuously?
The breaker is rated for a minimum operating temperature of 77 °F and carries a 10 kA interrupting rating at 120/240 V AC; no specific heat-dissipation figure is published.
What panelboard must I already have for this bolt-on breaker to fit?
It mounts on Square D NQOD panelboards and is compatible with the QO load-center series.
Will the QOB280 coordinate with older QO breakers already in my panel?
Yes, it shares the QO series frame size of 100 A and the same bolt-on mounting, so it installs alongside existing QO devices.