SQUARE D
SQUARE D QOB260 Miniature Circuit Breaker 60A 2 Pole 120/240V AC
A 60 A, two-pole bolt-on breaker for QO load centres, rated 120/240 V AC with a 10 kA interrupting capacity
- Protects 120/240 V AC circuits at 60 A
- Bolt-on mounting fits Square D QO panelboards
- 10 kA interrupting rating handles high fault currents
- Rated for 48 V DC and 77 °F minimum operating temperature
- Compact 3.1 in x 1.5 in x 2.9 in frame saves panel space
60 A Bolt-On Breaker for QO Panels
The Square D QOB260 is a two-pole miniature circuit breaker rated at 60 amps for 120/240 V AC and 48 V DC systems. It mounts with a bolt-on connection and uses a paddle actuator for manual switching. The unit carries a 10 kA interrupting rating at 120/240 V AC and fits within a 100 A QO frame.
Ideal for Standard QO Load Centres
Suited for electricians and facility managers adding or replacing branch protection in Square D NQOD panelboards where a standard 60 A two-pole breaker is required. Not a fit for panels that accept only plug-on breakers, for applications needing a higher interrupting rating, or for three-phase loads that demand a three-pole device.
Fits QO Series Enclosures
The breaker installs directly into compatible QO load centres using the bolt-on mounting style and lug terminals. Its 3.1 in length, 1.5 in width and 2.9 in depth allow it to occupy a standard two-pole slot without special spacing. Operating temperature minimum is 77 degrees F, so the enclosure must remain above that threshold.
Highlights
- Protects 120/240 V AC circuits at 60 A
- Bolt-on mounting fits Square D QO panelboards
- 10 kA interrupting rating handles high fault currents
- Rated for 48 V DC and 77 °F minimum operating temperature
- Compact 3.1 in x 1.5 in x 2.9 in frame saves panel space
Specifications
| Brand | SQUARE D |
|---|
Questions about this item
Does this QOB260 breaker require a Square D QO series panelboard to install?
Yes, it is designed for Square D QO and NQOD panelboards and uses a bolt-on mounting style.
Will the 10 kA interrupting rating at 120/240 V AC protect older branch circuits in the same panel?
The 10 kA AIR rating applies to the breaker itself; existing circuits remain protected by their own devices.
How can I verify the breaker is operating correctly after installation?
Confirm the paddle actuator moves firmly to the ON position and the circuit carries load without nuisance tripping.