We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

SQUARE D

SQUARE D QO230GFI 30A 2 Pole 120/240V Circuit Breaker

SKU CH-B3Q9-1TS62

A 30 A two-pole ground-fault circuit interrupter rated 120/240 V AC and 48 V DC with a 10 kA interrupting rating for QO load centres

  • Ground-fault protection trips at 5 mA for personnel safety
  • 30 A two-pole design handles 120/240 V AC loads
  • 10 kA interrupting rating clears high fault currents
  • Plug-in mounting fits QO and NQ load centres directly
  • Pressure-plate terminals accept wire without special tools

Ground-Fault Protection for 30 A Circuits

This Square D QO230GFI is a Class A ground-fault circuit interrupter rated at 30 amps and 120/240 V AC. It trips at a 5 mA leakage threshold to protect people from shock hazards. The two-pole design suits branch circuits that need both legs of a split-phase supply. It fits QO and NQ load centres using a plug-in mounting style.

Interrupting Capacity and Voltage Limits

The breaker carries a maximum AIR rating of 10 kA at 120/240 V AC, which defines the highest prospective fault current it can safely clear. It is also rated for 48 V DC, allowing use on certain low-voltage DC circuits. The 100 A frame size sets the physical envelope for the device within the panel. No other voltage or interrupting ratings apply to this model.

Plug-In Mounting and Pressure-Plate Terminals

A plug-in mounting style lets the breaker snap onto the panel bus without bolts, speeding installation and removal. Pressure-plate terminals accept conductors directly, securing them with a screw-down plate rather than a lug. The paddle actuator provides a clear visual indication of the on, off, or tripped position. The 4.1 in length determines the slot space required in the load centre.

Highlights

  • Ground-fault protection trips at 5 mA for personnel safety
  • 30 A two-pole design handles 120/240 V AC loads
  • 10 kA interrupting rating clears high fault currents
  • Plug-in mounting fits QO and NQ load centres directly
  • Pressure-plate terminals accept wire without special tools

Specifications

BrandSQUARE D

Questions about this item

Should I pick the 30 A two-pole version or a different amperage for my QO load center?

Choose the 30 A two-pole model when the branch circuit is rated for 30 A; other QO breakers carry different amp ratings and pole counts, so match the breaker to the circuit design.

What does the 5 mA Class A ground-fault rating mean once the breaker is installed?

It trips the breaker when leakage to ground exceeds 5 mA, providing personnel-level shock protection on the protected 120/240 V circuit.

Will the 10 kA interrupting rating at 120/240 V AC limit the fault current my panel can handle?

The breaker safely interrupts up to 10 kA at 120/240 V AC; the panel’s own short-circuit rating must be equal to or higher than that value.

Also in this aisle