SQUARE D
SQUARE D QO120VH 20A 1 Pole 120/240V circuit breaker
A single-pole miniature circuit breaker rated 20 A, 120/240 V AC with a 22 kA interrupting capacity for QO load centres
- High interrupting capacity protects circuits up to 22kA at 120/240V AC
- Single-pole 20A rating handles standard 120/240V residential branch circuits
- Plug-in mounting fits directly into compatible QO load centers and NQ panelboards
- Pressure-plate terminals accept wire without special tools for secure connections
- Compact 3in x .8in x 2.9in frame saves space in crowded panels
QO Series 20 A Breaker
The SQUARE D QO120VH is a single-pole miniature circuit breaker rated at 20 A for 120/240 V AC and 48 V DC. It plugs into QO load centres and NQ panelboards, providing high interrupting capacity protection for residential or light commercial branch circuits.
High Interrupting Thermal Protection
The breaker carries a 22 kA interrupting rating at 120/240 V AC, using a paddle actuator and pressure-plate terminals within a 100 A frame. Normal operation stays cool and quiet with no moving parts beyond the trip mechanism, drawing only the load current passed to the connected circuit.
Plug-In Fit for QO Panels
The unit measures 3 in long, .8 in wide and 2.9 in deep, matching the standard QO plug-in footprint. It requires a compatible QO or NQ panelboard slot and frees the installer from bolt-on wiring, while the single-pole width leaves adjacent spaces available for additional breakers.
Highlights
- High interrupting capacity protects circuits up to 22kA at 120/240V AC
- Single-pole 20A rating handles standard 120/240V residential branch circuits
- Plug-in mounting fits directly into compatible QO load centers and NQ panelboards
- Pressure-plate terminals accept wire without special tools for secure connections
- Compact 3in x .8in x 2.9in frame saves space in crowded panels
Specifications
| Brand | SQUARE D |
|---|
Questions about this item
How do I install the QO120VH breaker in a QO load center and what step is often missed?
Align the breaker with the bus stab, press firmly until it seats fully, then verify the paddle snaps into the locked position; the missed step is confirming the paddle locks rather than assuming it is seated.
What maintenance or replacement will the QO120VH need over time?
No routine maintenance is required; replace the breaker if it trips repeatedly without overload, shows discoloration at the pressure-plate terminals, or fails to reset after a fault.
What limit appears first during sustained loading on the QO120VH?
The 20 A thermal rating limits continuous current; the 22 kA interrupting capacity only applies during a short-circuit event, not during normal sustained operation.