SQUARE D
SQUARE D EDB34045 Miniature Circuit Breaker 45A 3 Pole
Miniature circuit breaker rated 45 A with three poles, 18 kA interrupting at 277/480 V AC and 125/250 V DC, bolt-on mounting for Square D NF panelboards
- Three-pole protection for three-phase circuits
- 45 A rating handles substantial branch loads
- 18 kA interrupting capacity at 277/480 V AC
- Bolt-on mounting fits Square D NF panelboards
- Compact 5.66 × 2.94 × 4.05 in frame saves panel space
EDB34045 45 A three-pole breaker
The SQUARE D EDB34045 is a bolt-on miniature circuit breaker rated 45 A at 277/480 V AC and 125/250 V DC. It installs directly into Square D NF panelboards and provides three-pole protection for three-phase loads. The toggle actuator gives clear on/off indication for maintenance and emergency switching. Frame size is 125 A EDB.
18 kA interrupting capacity
The breaker carries an 18 kA AIR rating at 277/480 V AC, suitable for typical commercial and light-industrial fault levels. It will handle continuous 45 A loads within its 104 °F maximum operating temperature. Higher fault currents or ambient temperatures beyond this limit require a different protective device. The lug terminals accept standard conductor sizes for the frame.
Bolt-on mounting for NF panelboards
Compatibility is limited to Square D NF series panelboards and load centres; the breaker will not fit other manufacturers' enclosures or Square D series with different mounting footprints. Three-pole construction occupies three adjacent pole spaces in the panel. Verify the panelboard schedule and available space before ordering.
Highlights
- Three-pole protection for three-phase circuits
- 45 A rating handles substantial branch loads
- 18 kA interrupting capacity at 277/480 V AC
- Bolt-on mounting fits Square D NF panelboards
- Compact 5.66 × 2.94 × 4.05 in frame saves panel space
Specifications
| Brand | SQUARE D |
|---|
Questions about this item
Will the 45 A, 3-pole EDB breaker fit in my existing Square D NF panelboard?
Yes, it is designed for Square D NF panelboards and uses a bolt-on mounting style with a 125 A EDB frame size.
How can I confirm the breaker is operating correctly after installation?
Switch the toggle actuator to the on position and verify that the circuit carries load up to 45 A without tripping, staying within the 104 °F maximum operating temperature.
Does the breaker come with line and load lugs or must they be purchased separately?
The unit includes a terminal connection lug for cable termination.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.