SQUARE D BDA36030 Molded Case Circuit Breaker 30A 3 Pole
A 30 A, three-pole molded-case breaker rated 525 V AC with a 25 kA interrupting rating at 277/408 V AC for industrial panels
- ColorGray
- 30 A rated current protects circuits reliably
- 25 kA interrupting rating clears heavy faults safely
- 525 V AC rating suits industrial power systems
- Thermal-magnetic trip gives fixed instantaneous protection
- I-Line mounting fits standard distribution panels
BDA36030 circuit breaker for three-phase panels
The SQUARE D BDA36030 is a molded-case circuit breaker rated at 30 A for three-phase AC systems. It mounts on I-Line bus and fits industrial control panels or electrical distribution equipment. The thermal-magnetic trip unit provides standard overcurrent protection with a fixed instantaneous setting. Gray housing and 5.39 in height match the POWERPACT B frame profile.
25 kA interrupting rating at 277/408 V AC
The single specification that decides fit is the maximum AIR of 25 kA at 277/408 V AC. This breaker will safely clear faults up to that level on a 525 V AC system. It is not DC rated, so it cannot protect DC bus sections or battery circuits. Verify the panel’s available fault current before specifying this frame.
Thermal-magnetic trip holds steady under sustained
Under continuous loading the thermal element responds to prolonged overcurrent without nuisance tripping. The fixed instantaneous trip engages only on short-circuit magnitudes up to the 25 kA rating. Mechanical lugs on the OFF end accept aluminum conductors for reliable termination during extended operation.
Highlights
- 30 A rated current protects circuits reliably
- 25 kA interrupting rating clears heavy faults safely
- 525 V AC rating suits industrial power systems
- Thermal-magnetic trip gives fixed instantaneous protection
- I-Line mounting fits standard distribution panels
Specifications
| Brand | SQUARE D |
|---|---|
| Color | Gray |
Questions about this item
What does the 30 A rating mean when the breaker is installed in a panel?
The breaker will carry up to 30 A continuously and trip on overloads or short circuits above that level, protecting the downstream circuit.
How does the 25 kA interrupting rating at 277/408 V AC limit the fault current it can safely clear?
It can safely interrupt short-circuit currents up to 25 kA on systems where the line-to-line voltage does not exceed 408 V AC.
What mounting style and panel space does the I-Line frame require?
It mounts on an I-Line bus and occupies a 125 A frame footprint with a height of 5.39 in.