Two-button 30 mm push-button station with momentary black start and red mushroom-head stop operators, 1NO/1NC contacts rated 5 A at 600 V AC, zinc enclosure rated NEMA 4 and IP66
- TypeIndustrial Electrical Controls & Automation
- Size30 mm
- Two start/stop push buttons in one compact station
- 30 mm operators fit standard industrial panels
- Zinc enclosure rated NEMA 4 and IP66 for harsh environments
- Contacts rated 5 A at 600 V AC and 24 V DC
- Wall-mount design with 1/2 to 3/4 in NPT hub
Industrial two-button control station
The Square D 9001BW250 is a wall-mounted control station with two push-button operators in black and red. It carries a Start/Stop legend and provides one normally-open and one normally-closed contact rated at 5 amps. The zinc enclosure measures 30 mm and meets NEMA 4 and IP66 ratings for dust and water ingress protection.
Rated for harsh environments
The enclosure is constructed from zinc with a gray finish and carries both NEMA 4 and IP66 ratings. Contacts are designated B600/P600 for 600 V AC and 24 V DC operation. The momentary mushroom-head action is designed for reliable switching in industrial settings without a mechanical interlock.
Wall mount with conduit entry
The station mounts directly to a wall and accepts conduit hubs from 1/2 inch to 3/4 inch NPT. Overall dimensions are 3.6 inches high, 2.76 inches wide and 4.25 inches deep. The dead-end layout suits single-station installations where a compact, sealed operator interface is required.
Highlights
- Two start/stop push buttons in one compact station
- 30 mm operators fit standard industrial panels
- Zinc enclosure rated NEMA 4 and IP66 for harsh environments
- Contacts rated 5 A at 600 V AC and 24 V DC
- Wall-mount design with 1/2 to 3/4 in NPT hub
Specifications
| Brand | SQUARE D |
|---|---|
| Type | Industrial Electrical Controls & Automation |
| Size | 30 mm |
Questions about this item
How do I wire the 1/2 in to 3/4 in NPT hub on the 9001BW250, and what step do people skip?
Thread conduit into the hub, tighten the locknut, then pull wires through; the step often missed is seating the gasket so the IP66 seal holds.
Which part of the 9001BW250 wears out first and needs replacement?
The push-button contacts rated 5A at 600V AC will wear after repeated momentary cycles; the zinc enclosure and mushroom heads typically outlast them.
What thermal or electrical limit appears first during continuous operation of the 9001BW250?
The 5A contact rating at 600V AC is the limiting factor; sustained loads above that will overheat the contacts before the IP66 enclosure reaches any temperature limit.