SIEMENS
SIEMENS B360 Circuit Breaker BL 60A 3P 240V 10kA
Three-pole bolt-on breaker rated 60 A at 240 V AC with a 10 kA interrupting capacity for Siemens P1 panelboards
- 60 A three-pole protection for 240 V three-phase circuits
- 10 kA interrupting rating clears heavy fault currents safely
- Bolt-on mounting fits Siemens P1 panelboards directly
- 125 A frame size supports 8 AWG minimum conductors
- Compact 3.7 × 4.5 × 12.9 in profile saves panel space
Three-pole 60 A protection for Siemens P1 panels
This bolt-on miniature circuit breaker delivers 60 A of overcurrent protection across three phases at 240 V AC. It is built for Siemens P1 panelboards and load centres that accept the BL series frame. The toggle actuator provides clear on-off indication for maintenance staff.
10 kA interrupting rating at 240 V AC
The single figure that decides fit is the maximum AIR of 10 kA at 240 V AC. If the available fault current at the installation point exceeds this value, the breaker cannot safely clear a short circuit. Verify the system study before specifying this device.
Sustained 60 A carry within a 125 A frame
The 125 A frame size allows the breaker to carry its full 60 A rating continuously without nuisance tripping. Thermal-magnetic operation responds to prolonged overloads while the 10 kA magnetic trip handles severe faults. Lug terminals accept conductors down to 8 AWG for secure, low-resistance connections.
Highlights
- 60 A three-pole protection for 240 V three-phase circuits
- 10 kA interrupting rating clears heavy fault currents safely
- Bolt-on mounting fits Siemens P1 panelboards directly
- 125 A frame size supports 8 AWG minimum conductors
- Compact 3.7 × 4.5 × 12.9 in profile saves panel space
Specifications
| Brand | SIEMENS |
|---|
Questions about this item
What does the 60 A rating mean once the breaker is installed in a panel?
It means the breaker will carry up to 60 A continuously and trip if the current exceeds that value, protecting the downstream wiring in a three-phase circuit.
What does the 10 kA interrupting rating at 240 V AC cap in practice?
It caps the maximum prospective short-circuit current the breaker can safely interrupt to 10 kA on a 240 V AC supply.
What does the bolt-on mounting style need to fit in a Siemens P1 panelboard?
It needs a bolt-on bus stab in a Siemens P1 panelboard and accepts wire down to 8 AWG on its lug terminals.
Also in this aisle
People compared these