SIEMENS
SIEMENS 52BP2E2AB Illuminated Push Button 30mm 1NO/1NC Red 120V AC LED
30 mm illuminated mushroom push-button with 120 V AC LED, 1NO/1NC contacts rated 10 A at 600 V AC, NEMA 1, 3, 3R, 4, 4X, 12, 13
- Red LED illumination for clear status indication
- 30 mm mushroom head with maintained push-pull action
- 10 A contact rating at 600 V AC for reliable switching
- NEMA 1, 3, 3R, 4, 4X, 12, 13 enclosure ratings suit harsh environments
- 120 V AC full-voltage LED module simplifies wiring
Siemens 30 mm Illuminated Push Button
This Siemens 52BP2E2AB is a maintained push-pull operator with a 44 mm red mushroom head and integrated 120 V AC LED illumination. It mounts in a standard 30 mm panel cut-out and carries a single 1NO/1NC contact block rated at 10 A and 600 V AC. The epoxy-coated zinc die-cast bezel and epoxy base meet NEMA 1, 3, 3R, 4, 4X, 12 and 13 ratings for industrial environments.
For Emergency-Stop and Safety Interlock Panels
The maintained action and mushroom profile suit emergency-stop stations, safety interlocks and manual motor-control panels where a visible red status is required. Buyers needing momentary push-button operation, a different actuator colour or a non-illuminated operator should select another model.
120 V AC Full-Voltage LED Lamp Module
The built-in LED module runs directly on 120 V AC supply without an external transformer; the replacement lamp is part number 52AEE2. Verify that your control-circuit voltage matches this rating before installation.
Highlights
- Red LED illumination for clear status indication
- 30 mm mushroom head with maintained push-pull action
- 10 A contact rating at 600 V AC for reliable switching
- NEMA 1, 3, 3R, 4, 4X, 12, 13 enclosure ratings suit harsh environments
- 120 V AC full-voltage LED module simplifies wiring
Specifications
| Brand | SIEMENS |
|---|
Questions about this item
How do I replace the LED lamp when it eventually fails?
The lamp is a full-voltage 120V AC LED module; the replacement part number is 52AEE2 and it swaps directly into the mushroom-head operator.
What contact rating limits how long I can run a 10 A load?
The contacts are rated 10 A at 600 V AC with NEMA designation A600/P600, so sustained current must stay at or below 10 A.
How much heat does the 120 V LED generate during all-day operation?
The LED lamp module is a low-power 120V AC type, so heat at the 44 mm mushroom head remains low during continuous use.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.