Photoelectric retro-reflective sensor with PNP output, 0.01 m to 14 m sensing range, 10–30 V DC supply, IP67 enclosure, and M12 connector
- Detects objects up to 14 m with retro-reflective sensing
- PNP output handles 100 mA for direct load switching
- IP67 enclosure resists dust and water ingress
- Operates from –25 °C to +55 °C in harsh environments
- Includes P250 reflector and mounting bracket for quick setup
Industrial sensing for automation engineers
The SICK WL260-F470 is a photoelectric retro-reflective sensor designed for industrial automation tasks. Its PNP switching output and selectable light/dark mode suit PLC integration in packaging, material handling and assembly lines.
Range and response in practice
The sensor detects targets from 0.01 m up to 14 m maximum, with a typical operating range of 9.5 m or 11.5 m depending on reflector choice. A 1.5 ms response time and 333 Hz switching frequency support fast conveyor sequences, while the visible red LED spot reaches 240 mm diameter at 8 m distance.
Bundled reflector and bracket simplify mounting
Supplied P250 reflector and BEF-W260 mounting bracket enable immediate installation without separate procurement. The IP67-rated ABS housing tolerates wash-down environments from –25 °C to +55 °C, and the M12 4-pin connector fits standard fieldbus cabling.
Highlights
- Detects objects up to 14 m with retro-reflective sensing
- PNP output handles 100 mA for direct load switching
- IP67 enclosure resists dust and water ingress
- Operates from –25 °C to +55 °C in harsh environments
- Includes P250 reflector and mounting bracket for quick setup
Specifications
| Brand | Sick |
|---|---|
| Model | SICK WL260-F470 |
Questions about this item
Will the sensor's 10 V DC to 30 V DC supply voltage work with my existing 24 V DC control system?
Yes, the sensor operates on a 10 V DC to 30 V DC supply voltage range, making it directly compatible with a standard 24 V DC control system without requiring additional voltage converters.
How can I verify the PNP switching output is functioning correctly after installation?
Connect the output to your PLC input; the indicator LED on the sensor housing will illuminate when the output switches, confirming the PNP signal transitions between 0 V and the supply voltage as the beam is broken or restored.
Does the package include the M12 connection cable needed for wiring?
The box includes the WL260-F470 sensor, a P250 reflector, and a BEF-W260 mounting bracket; the 4-pin M12 connection cable must be purchased separately.