Sick VL18-3E3312 photoelectric retro-reflective sensor NPN
Photoelectric retro-reflective sensor with 0.05 m to 3.7 m sensing range, NPN output and IP67-rated metal housing
- Retro-reflective detection up to 3.7 m sensing range
- NPN light-switching output with 2 ms response time
- Brass nickel-plated metal housing rated IP67 for harsh environments
- Operates on 10–30 V DC with 30 mA power consumption
- 2 m PVC cable with 0.14 mm² conductors ready to install
Sick VL18-3E3312 retro-reflective sensor
The Sick VL18-3E3312 is a photoelectric retro-reflective sensor with an NPN switching output designed for industrial detection tasks. Its cylindrical angled housing measures 60.6 mm and holds visible red LED optics behind a PMMA cover. The unit operates on 10 V DC to 30 V DC supply voltage with a 2 ms response time and IP67 enclosure rating.
Suited for DC control systems needing
This sensor suits automation lines, packaging equipment and material-handling systems that require a 0.05 m to 3.7 m sensing range with potentiometer adjustment. It is not for applications demanding PNP switching logic, analogue output or through-beam detection principles. Buyers needing longer range, fibre-optic heads or IO-Link communication should look elsewhere.
Verify supply voltage wiring
Confirm your control cabinet provides 10 V DC to 30 V DC with ripple below 10 % and that the 2 m PVC cable with 0.14 mm² conductors reaches the termination point. Ensure ambient temperature stays within –25 °C to +70 °C and that a suitable reflector can be positioned within the 2.8° angle of dispersion for reliable operation.
Highlights
- Retro-reflective detection up to 3.7 m sensing range
- NPN light-switching output with 2 ms response time
- Brass nickel-plated metal housing rated IP67 for harsh environments
- Operates on 10–30 V DC with 30 mA power consumption
- 2 m PVC cable with 0.14 mm² conductors ready to install
Specifications
| Brand | Sick |
|---|---|
| Model | SICK VL18-3E3312 |
Questions about this item
What voltage supply do I need to run the VL18-3E3312 sensor?
The sensor operates on 10 V DC to 30 V DC with a maximum ripple of 10 percent and draws up to 30 mA.
Can I use this NPN output sensor with a PLC input card that expects PNP signals?
No, the VL18-3E3312 provides an NPN switching output; it pulls the load to ground, so a PNP input card will not register the signal correctly.
How can I verify the sensor is detecting the reflector at the rated 3.7 m range after installation?
Align the visible red LED spot on the reflector, then check that the output switches within 2 ms as the target enters the beam; the potentiometer lets you fine-tune the switching point.