Schneider Electric
Schneider Electric 9001KYK32 Control Station 3-Button Blk/Red
A three-button industrial control station with momentary push buttons in black and red, rated 10 A at 600 V AC and IP66, in a zinc enclosure for wall mounting
- Engine BrandSCHNEIDER ELECTRIC
- Engine Size30 mm
- Three momentary push buttons for up/down/stop control
- NEMA 1, 3, 4, 13 and IP66 enclosure resists dust and water jets
- Zinc housing with 3/4 in NPT hub suits wall mounting
- Contacts rated 10A at 600V AC and 2.5A at 24V DC
- Compact 30 mm operator size fits standard 3.53 x 3.58 in footprint
Industrial three-button control station
The Schneider Electric 9001KYK32 is a wall-mounted control station built for industrial environments. It houses three momentary push buttons in a zinc enclosure rated NEMA 1, 3, 4 and 13 with IP66 protection. Operators use it for direct machine control such as up, down and stop functions.
Contact rating determines suitability
Each operator provides 3NO and 3NC contacts rated at 10 A at 600 V AC and 2.5 A at 24 V DC, matching the A600/Q600 designation. The 30 mm button size and 3/4 inch NPT hub are fixed mechanical details that must match the panel cut-out and conduit entry.
Zinc enclosure handles sustained exposure
The die-cast zinc housing resists corrosion and impact during continuous operation in wet or dusty conditions. Momentary action returns each button automatically, preventing unintended latching during prolonged use. Wall mounting keeps the unit secure under vibration.
Highlights
- Three momentary push buttons for up/down/stop control
- NEMA 1, 3, 4, 13 and IP66 enclosure resists dust and water jets
- Zinc housing with 3/4 in NPT hub suits wall mounting
- Contacts rated 10A at 600V AC and 2.5A at 24V DC
- Compact 30 mm operator size fits standard 3.53 x 3.58 in footprint
Specifications
| Engine Brand | SCHNEIDER ELECTRIC |
|---|---|
| Engine Size | 30 mm |
Questions about this item
What does the 30 mm operator size mean once the station is mounted on a machine?
The 30 mm size is the standard cut-out diameter for each push button, so the three operators fit the same panel openings used across most industrial control panels.
How do the NEMA 1, 3, 4, 13 and IP66 ratings limit where the enclosure can be installed?
Those ratings certify the zinc enclosure against dust, water jets, oil and non-corrosive coolants, so it can be wall-mounted indoors or outdoors in wet, dirty environments.
What clearance does the 7.5 in depth and 3/4 in NPT hub need for conduit entry?
The station projects 7.5 in from the mounting surface, and the 3/4 in NPT hub requires a matching conduit fitting with enough rear space for wiring bends.