Robertshaw 780-845 Ignition Module Intermittent Pilot 24 V HVAC Control
Intermittent-pilot ignition module for 24 V gas systems, operating from -40 °F to 175 °F with 90-second lockout and three retries
- TypeGas Ignition & Pilots
- Reliable ignition with intermittent pilot design
- Operates from -40 to 175 Degrees F
- Three retries before 90-second lockout
- Automatic reset after one hour
- 24 V control with 1 A main valve output
Intermittent Pilot Ignition Module
The Robertshaw 780-845 is an intermittent pilot ignition module designed for gas-fired HVAC equipment. It operates on a 24 V supply and manages the ignition sequence for heating systems. The control provides automatic reset after a one-hour lockout period.
Suitable for gas furnace and boiler repairs
This module suits technicians replacing a failed intermittent pilot control on compatible equipment. It is not for installers needing a direct spark or hot surface ignition system. Buyers requiring a different lockout timing or valve current rating should verify specifications before purchasing.
90-second ignition cycle with three retries
The control attempts ignition for 90 seconds per cycle and allows up to three retries before lockout. A six-minute pre-purge precedes each trial. This timing sequence determines compatibility with the appliance safety requirements.
Highlights
- Reliable ignition with intermittent pilot design
- Operates from -40 to 175 Degrees F
- Three retries before 90-second lockout
- Automatic reset after one hour
- 24 V control with 1 A main valve output
Specifications
| Type | Gas Ignition & Pilots |
|---|---|
| Brand | ROBERTSHAW |
| Model | 780-845 |
Questions about this item
What comes with the Robertshaw 780-845 module and is a separate flame sensor required?
The module is supplied as a single ignition control unit; a compatible flame sensor must be purchased separately to complete the intermittent pilot system.
How do I decide between the 90-second lock-out and the 6-minute pre-purge timing for my furnace?
The 90-second lock-out is the safety shut-off after failed ignition attempts, while the 6-minute pre-purge runs before each trial; both are fixed timings on this model, not selectable options.
What does the 0.7 mA flame sensor current mean when the module is installed in a live HVAC system?
It is the minimum current the module must detect from the flame rod to confirm burner ignition; if the measured current falls below 0.7 mA the control will lock out after three retries.