Nomaco Kflex
Nomaco Kflex 801-T-068238 Tee Pipe Fitting Insulation
Elastomeric tee insulation for 2 3/8 inch tube OD, Buna-N/PVC closed-cell foam rated to 220 °F with UL 94 flame spread index 25 and R-value 4.9
- TypeTarps
- Antimicrobial closed-cell foam resists mould growth
- UL 94 rated material meets flame spread index 25
- Withstands temperatures from -297 °F to 220 °F
- R-value 4.9 reduces thermal loss on piping
- Plenum rated for safe use in air-handling spaces
Elastomeric Tee Fitting for 2 in Pipe
This pre-formed tee insulation fits copper or iron pipe with a 2 3/8 in outside diameter. It is supplied unslit for a continuous vapour barrier on chilled-water, refrigerant or hot-water lines. The closed-cell Buna-N rubber/PVC foam resists microbial growth and meets UL 94 and a 25 flame-spread index.
R-Value 4.9 at 3/4 in Wall Thickness
The single figure that determines thermal performance is the 4.9 R-value provided by the 3/4 in wall. It maintains that resistance from -297 °F up to 220 °F, so the part suits both cryogenic and high-temperature hydronic systems without additional jacketing.
Push-On Installation Over Clean Pipe
Slide the tee onto the fitting before brazing or press-connecting the joint, then seal the seams with compatible contact adhesive. The unslit design requires planning the fitting sequence in advance; once the joint is made the insulation cannot be wrapped around it.
Highlights
- Antimicrobial closed-cell foam resists mould growth
- UL 94 rated material meets flame spread index 25
- Withstands temperatures from -297 °F to 220 °F
- R-value 4.9 reduces thermal loss on piping
- Plenum rated for safe use in air-handling spaces
Specifications
| Brand | K-FLEX USA |
|---|---|
| Type | Tarps |
Questions about this item
What does the R-value of 4.9 mean once the tee fitting is installed on a 2-inch pipe?
An R-value of 4.9 indicates the insulation's thermal resistance, helping to reduce heat loss or gain on the pipe fitting at operating temperatures between -297 and 220 degrees Fahrenheit.
How does the UL 94 standard and flame spread index of 25 affect where this insulation can be used?
The UL 94 rating and a flame spread index of 25 mean the material meets plenum rating requirements, allowing installation in air-handling spaces per building codes.
What are the physical dimensions needed for this tee fitting to fit my pipe?
This tee fitting is designed for a 2-inch pipe size with a 2 3/8-inch outside diameter, featuring a 3/4-inch wall thickness and an unslit installation style.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.