Matrix
Matrix MPS-6000S-600-10 600V 10A 6000W industrial power supply
A programmable DC bench supply delivering 0–600 V at 10 A with 6000 W output, PWM regulation, five-digit readout, OVP/OCP/OTP/short-circuit protection, key lock, remote sense.
- TypeMATRIX MPS-6000S-600-10 High Voltage Programmable DC Power S
- Watts6000 watts
- Surge Wats6000 watts
- Engine BrandMATRIX
- Voltage600 volts
- Circuit BreakerMATRIX MPS-6000S-600-10 High Voltage Programmable DC Power S
- Programmable 0-600 V output covers wide test ranges
- 10 A maximum current delivers 6000 W for demanding loads
- Five-digit simultaneous voltage and current display gives precise readings
- OVP OCP OTP and short-circuit protection safeguard connected equipment
- RS-232 and RS-485 interfaces enable remote automation
6 kW Programmable DC Supply
The Matrix MPS-6000S-600-10 delivers 0 to 600 V at up to 10 A for bench test and lab applications. It accepts single-phase 220 V AC at 50 Hz and provides a simultaneous five-digit readout of voltage and current.
Forced-air cooling with protection circuits
Internal PWM modulation and high-gain amplification keep output stable under continuous 6000 W load. Over-voltage, over-current, over-temperature and short-circuit safeguards activate automatically without operator intervention.
RS-232 and RS-485 remote interfaces
Serial ports allow automated voltage and current programming from external controllers. Front-panel preset keys and a key-lock function store recurring set-ups and prevent accidental changes during test runs.
Highlights
- Programmable 0-600 V output covers wide test ranges
- 10 A maximum current delivers 6000 W for demanding loads
- Five-digit simultaneous voltage and current display gives precise readings
- OVP OCP OTP and short-circuit protection safeguard connected equipment
- RS-232 and RS-485 interfaces enable remote automation
Specifications
| Type | MATRIX MPS-6000S-600-10 High Voltage Programmable DC Power Supply 600V 10A 6KW High-Power with OVP, OCP, OTP, Short Circuit Protection, Input AC 220V 50Hz, adjustable bench dc power supply 6000w variable lab dc power supply switching dc power supply |
|---|---|
| Watts | 6000 watts |
| Surge Wats | 6000 watts |
| Engine Brand | MATRIX |
| Voltage | 600 volts |
| Circuit Breaker | MATRIX MPS-6000S-600-10 High Voltage Programmable DC Power Supply 600V 10A 6KW High-Power with OVP, OCP, OTP, Short Circuit Protection, Input AC 220V 50Hz |
| Size/Dimensions | 17 in x 20 in x 3.5 in |
| Horsepower | 6000 watts |
| Input Voltage | MATRIX MPS-6000S-600-10 High Voltage Programmable DC Power Supply 600V 10A 6KW High-Power with OVP, OCP, OTP, Short Circuit Protection, Input AC 220V 50Hz |
| Output Voltage | MPS-6000S-600-10, MATRIX MPS-6000S-600-10 High Voltage Programmable DC Power Supply 600V 10A 6KW High-Power with OVP, OCP, OTP, Short Circuit Protection, Input AC 220V 50Hz, adjustable bench dc power supply 6000w variable lab dc power supply switching dc power supply |
| Output Amps | MPS-6000S-600-10, MATRIX MPS-6000S-600-10 High Voltage Programmable DC Power Supply 600V 10A 6KW High-Power with OVP, OCP, OTP, Short Circuit Protection, Input AC 220V 50Hz |
| Input Amps | 2U, MATRIX MPS-6000S-600-10 High Voltage Programmable DC Power Supply 600V 10A 6KW High-Power with OVP, OCP, OTP, Short Circuit Protection, Input AC 220V 50Hz |
| Style | adjustable bench dc power supply 6000w variable lab dc power supply switching dc power supply |
| Operating Frequency | not_applicable |
| Material | Metal |
| Regulation | not_applicable |
| Ripple | MATRIX MPS-6000S-600-10 High Voltage Programmable DC Power Supply 600V 10A 6KW High-Power with OVP, OCP, OTP, Short Circuit Protection, Input AC 220V 50Hz |
| Features | adjustable bench dc power supply 6000w variable lab dc power supply switching dc power supply, MATRIX MPS-6000S-600-10 High Voltage Programmable DC Power Supply 600V 10A 6KW High-Power with OVP, OCP, OTP, Short Circuit Protection, Input AC 220V 50Hz |
| Parts | 3 Years |
| Labor | 3 Years |
Questions about this item
How do I install the bench supply on a work surface and what step is often missed?
Place the metal chassis on a stable bench, connect the single-phase AC 220V 50Hz input to the rear terminals, then enable the remote voltage compensation leads at the load to avoid regulation errors.
What maintenance or replacement will the MPS-6000S-600-10 need during its service life?
The unit uses imported key components rated for continuous full-load operation; plan periodic fan and filter cleaning, and expect electrolytic capacitor replacement after several years of 6000W duty.
Which limit appears first when the supply runs at 600V 10A continuously?
Over-temperature protection (OTP) will trip before the 6000W thermal design limit is exceeded, shutting down output until internal temperatures fall to a safe level.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.