Intermatic
Intermatic T101PCD82 24-Hour SPST Timer Switch 120V 40A
A 24-hour electromechanical timer switch with SPST contact, 120V AC and 40A rating in a NEMA 3R polycarbonate enclosure
- 24-hour scheduling with up to 12 on/off cycles daily
- 40 A SPST switching handles 2 hp motor loads at 120 V
- NEMA 3R polycarbonate enclosure withstands -40 °F to 130 °F
- Surface-mount design with clear door for quick visual status checks
- Includes four trippers; extra trippers available under part 156T1978A
24-Hour SPST Timer Switch
The Intermatic T101PCD82 is a 24-hour electromechanical timer switch rated for 120V AC and 40A. It uses a single-pole single-throw contact rated at 2 hp at 120V and includes four trippers for scheduling up to twelve on/off cycles per day. A clear polycarbonate door protects the dial inside a NEMA 3R gray enclosure.
Suited for daily load control.
This timer suits installers who need a simple daily repeat cycle for pumps, lighting or HVAC loads up to 40A. It operates from -40°F to 130°F and mounts on a flat surface. Buyers who require multiple independent schedules, day-skipping features or astronomic timing should look at a different device.
Handles up to 23 hours on with twelve daily cycles
The dial allows a minimum on-time of one hour and a maximum of twenty-three hours per cycle, with twelve cycles available every twenty-four hours. Four trippers are supplied and extras are available under part number 156T1978A. The mechanism does not support shorter intervals, skip-day programming or battery-backed timekeeping during power loss.
Highlights
- 24-hour scheduling with up to 12 on/off cycles daily
- 40 A SPST switching handles 2 hp motor loads at 120 V
- NEMA 3R polycarbonate enclosure withstands -40 °F to 130 °F
- Surface-mount design with clear door for quick visual status checks
- Includes four trippers; extra trippers available under part 156T1978A
Specifications
| Brand | Intermatic |
|---|
Questions about this item
Will the 120 V AC supply and 40 A rating handle my existing pool pump motor?
The timer is rated for 120 V AC and 40 A with a 2 hp motor load at 120 V, so it will control a compatible single-phase pump within those limits.
Can I keep using my current 156T1978A trippers with this unit?
Yes, the switch includes four trippers and accepts extra trippers identified as 156T1978A, so your existing ones will fit.
How do I verify the timer is cycling correctly after I wire it?
Watch the dial advance through the 24-hour face; each on/off tripper should trigger the SPST contacts up to 12 times per day, confirming proper operation.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.