Honeywell
Honeywell PVL4024NS VAV controller 2 analog output Spyder LON programmable
Programmable VAV controller with two analog outputs and LON connectivity for HVAC zone control
- VAV control with two analog outputs
- LON programmable for building automation
- Spyder platform integration ready
- Honeywell HVAC controller model PVL4024NS
- New condition for reliable installation
16-channel IP video recorder
This network video recorder handles up to sixteen IP camera channels and ships with four terabytes of storage in a front-swap four-bay chassis. It is built for commercial installations that need continuous recording and instant search across multiple sites. The unit operates on 100 to 240 volt AC power and draws 220 watts under load. Remote access is available through Bosch mobile and desktop clients.
Installers needing VGA output and local storage
The recorder suits technicians who require direct VGA monitoring and up to eight terabytes of internal capacity without external arrays. It is not intended for deployments that rely on HDMI or DisplayPort outputs, nor for systems that demand more than sixteen simultaneous streams. Buyers who need higher channel counts or different video interfaces should consider alternative platforms.
16 IP channels and 4 TB baseline storage
The decisive specification is the sixteen-channel licence paired with a four-terabyte baseline that can be expanded to eight terabytes using the four front-accessible bays. This combination determines whether the unit matches the camera count and retention requirements of the project.
Highlights
- VAV control with two analog outputs
- LON programmable for building automation
- Spyder platform integration ready
- Honeywell HVAC controller model PVL4024NS
- New condition for reliable installation
Specifications
No published specifications for this item yet.
Questions about this item
Does the PVL4024NS mount on a standard DIN rail or require a specific panel cut-out?
The controller is designed for direct panel mounting inside a VAV box enclosure; no DIN rail clip is included.
What wiring step is most often missed when commissioning the Spyder LON programmable VAV controller?
Technicians frequently forget to terminate the LON bus with the correct impedance at the last device, causing communication errors.
Which field-replaceable component in the PVL4024NS typically reaches end of life first?
The onboard backup battery that retains schedules and set-points is the only user-replaceable part and usually lasts several years.