HNZXIB
HNZXIB 58L -86°C Vertical Ultra-Low Temperature Freezer laboratory supply
A 58-litre vertical ultra-low temperature freezer reaching -86 °C with microprocessor control and 0.1 °C accuracy
- TypeLab Chemicals
- Voltage110V
- 58 L capacity stores large sample volumes
- 86 °C minimum temperature protects ultra-low storage needs
- 1 °C control accuracy keeps samples stable
- 50 % energy saving reduces running costs
- 72-hour battery backup maintains alarms during power loss
58L vertical freezer for lab storage
The HNZXIB 58L vertical ultra-low temperature freezer provides 58 litres of capacity for laboratories that require reliable sample preservation at extreme cold. It operates on a 110 V, 60 Hz supply and draws 3.1 A at a rated 450 W. The 304 stainless steel interior resists corrosion and is designed for friendly use in demanding environments. Digital microprocessor control maintains the chamber between -40 °C and -86 °C with 0.1 °C accuracy.
Upgrades from higher-consumption units
The mixed-refrigerant, single-level auto-cascade refrigeration system reduces energy consumption by 50 % compared with conventional designs while improving temperature uniformity by 30 %. Direct cooling and manual defrost simplify the refrigerant circuit, using fewer components for easier maintenance. Power consumption is 6.5 kW per 24 hours, making the jump worthwhile for facilities that run freezers continuously and need lower operating costs without sacrificing the -86 °C lower limit.
Check voltage, clearance and alarm needs
Verify that the installation site supplies 110 V, 60 Hz power and can accommodate the exterior footprint of 540 × 620 × 1115 mm plus clearance for the four lockable casters. The built-in backup battery sustains the digital display and audible-visual alarms for 72 hours during a power outage, so confirm that the alarm features meet your monitoring protocol. Keyboard lock and password protection prevent unauthorised parameter changes, and the removable inner door and condenser dust gauze simplify routine cleaning and defrosting.
Highlights
- 58 L capacity stores large sample volumes
- 86 °C minimum temperature protects ultra-low storage needs
- 1 °C control accuracy keeps samples stable
- 50 % energy saving reduces running costs
- 72-hour battery backup maintains alarms during power loss
Specifications
| Type | Lab Chemicals |
|---|---|
| Voltage | 110V |
Questions about this item
What exterior dimensions and casters does the 58L freezer need for placement?
The unit measures 540 mm wide, 620 mm deep and 1115 mm high, and sits on four lockable casters for moving and fixing it in place.
How is the freezer installed and what step is often missed?
Connect the 110 V, 60 Hz supply rated at 450 W and 3.1 A, then set the microprocessor controller and digital display; the step often missed is allowing the cooling-system restart delay after a power interruption.
What maintenance will the 58L freezer require later?
Clean the removable condenser dust gauze regularly, defrost manually using the removable inner door, and rely on the built-in back-up battery to keep alarms and temperature display running for up to 72 hours without mains power.