Hayward Flow Control
Hayward Flow Control TBH2075ASTV0Z00 Ball Valve 3/4 in
Manual two-way ball valve with CPVC body handles corrosive chemicals and water at 250 psi maximum operating pressure
- CPVC body resists corrosive chemicals and water
- Full-port Z-ball allows unrestricted flow through 3/4 in valve
- Three-piece true-union design simplifies installation and maintenance
- Locking tee handle secures valve position during operation
- Rated for 250 psi maximum operating pressure
Manual Two-Way Ball Valve
This CPVC ball valve handles corrosive chemicals and water in industrial piping systems. The true-union, three-piece design allows inline maintenance without cutting pipe. A locking tee handle prevents accidental actuation during service.
Practical Limits of 250 psi Rating
The valve is rated for 250 psi maximum operating pressure with non-shock cold water. It carries no steam, combustible gas or vacuum rating. Surges above 250 psi or use with unrated media will compromise the seal and body integrity.
Replaces Single-Union or Non-Locking Valves
The true-union ends and locking handle upgrade installations where frequent disassembly or tamper resistance are required. The jump is worth it when maintenance intervals are short or safety protocols demand positive handle locking.
Highlights
- CPVC body resists corrosive chemicals and water
- Full-port Z-ball allows unrestricted flow through 3/4 in valve
- Three-piece true-union design simplifies installation and maintenance
- Locking tee handle secures valve position during operation
- Rated for 250 psi maximum operating pressure
Specifications
| Brand | HAYWARD FLOW CONTROL |
|---|
Questions about this item
Should I pick the 3/4 inch True Union Z-Ball version for my piping system?
The 3/4 inch True Union Z-Ball design allows easy removal for maintenance without cutting pipe, and the full-port CPVC ball matches the line size for unrestricted flow.
How does the 250 psi rating hold up when the valve is installed in a live chemical line?
The CPVC body and ball are rated for 250 psi operating pressure with corrosive chemicals and water, and the locking tee handle prevents accidental actuation under pressure.
What does the True Union connection mean for installation and pressure limits?
True Union ends let you thread or solvent-weld the valve into the system, and the 250 psi maximum operating pressure applies once the unions are properly tightened.