GE
GE THQL21WY20 Circuit Breaker 20A 2 Pole 120/240V
A 20 A, two-pole miniature circuit breaker with switched neutral, plug-in mounting and 10 kA interrupting rating for Power Mark Gold load centres
- 20 A switched-neutral protection for single-phase 120/240 V circuits
- 10 kA interrupting rating handles high fault currents safely
- Plug-in mounting fits Power Mark Gold and AQ load centres
- Screw-clamp terminals accept solid or stranded conductors securely
- Compact 3.3 × 2 × 2.4 in frame saves panel space
What This Breaker Does
The GE THQL21WY20 is a 20 A moulded-case circuit breaker designed for 120/240 V AC single-phase systems. It uses a switched-neutral, two-pole toggle mechanism and plugs into compatible AQ load centres or Power Mark Gold panels. The unit carries a 10 kA interrupting rating at its rated voltage.
Check Your Panel First
Verify that the load centre accepts THQL-series plug-in breakers and that the bus is rated for at least 100 A frame size. Confirm the panel provides two adjacent spaces for a two-pole device and that the screw-clamp terminals suit your wire gauge. The breaker is not rated for DC applications.
Sustained Load Behaviour
Under continuous operation the breaker will carry its 20 A rating within the 100 A frame thermal limits defined by the THQL design. The 10 kA AIR rating applies to short-circuit interruption at 120/240 V AC, not to prolonged overload endurance. Ambient temperature inside the enclosure will affect trip timing as with any thermal-magnetic device.
Highlights
- 20 A switched-neutral protection for single-phase 120/240 V circuits
- 10 kA interrupting rating handles high fault currents safely
- Plug-in mounting fits Power Mark Gold and AQ load centres
- Screw-clamp terminals accept solid or stranded conductors securely
- Compact 3.3 × 2 × 2.4 in frame saves panel space
Specifications
| Brand | GE |
|---|
Questions about this item
Does the THQL21WY20 come with mounting hardware or must I buy screws separately?
The breaker uses a plug-in mounting style for compatible load centers and has screw-clamp terminals for wire connections; separate mounting screws are not required.
How do I decide between the 20 A version and other amp ratings in the THQL series?
Choose the 20 A rating when the branch circuit is designed for a 20 ampere load; other THQL ratings exist for different circuit ampacities.
What does the 10 kA AIR rating mean when the breaker is installed in a panel?
It indicates the breaker can safely interrupt up to 10 kA of fault current at 120/240 V AC in a Power Mark Gold or AQ panel.