We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

GE

GE THQL2135 Molded Case Circuit Breaker 35A 2 Pole 120/240V AC

SKU CH-083B-4RJTB

A 35 A two-pole breaker rated 120/240 V AC with 10 kA interrupting capacity for Power Mark Gold and AQ panels

  • 35 A rating protects 120/240 V circuits from overload
  • 10 kA interrupting capacity stops heavy fault currents safely
  • Two-pole design handles single-phase loads on both hot legs
  • Plug-in mounting fits AQ and Power Mark Gold load centers
  • Toggle actuator gives clear on/off status at a glance

GE THQL2135 Circuit Breaker 35A

The GE THQL2135 is a standard molded case circuit breaker rated at 35 amps for 120/240V AC single-phase systems. It features a two-pole toggle actuator and a plug-in mounting style designed for compatible load centers. The unit carries a 10kA interrupting rating at the rated voltage and uses a lug terminal connection within a 100A frame size.

Replaces standard 35A two-pole breakers

This breaker serves as a direct replacement for worn or tripped standard 35A two-pole units in supported GE Power Mark Gold and AQ series panels. The upgrade is worth it when the existing breaker shows nuisance tripping, physical damage, or fails to reset, restoring reliable overcurrent protection for the branch circuit.

Suits electricians maintaining GE load centers

It suits electricians and maintenance staff servicing GE Power Mark Gold load centers or AQ lighting panels requiring a 35A two-pole device. Buyers needing a DC voltage rating, a higher interrupting capacity, or a different mounting style such as bolt-on should look at other series. The plug-in design limits use to compatible panelboards only.

Highlights

  • 35 A rating protects 120/240 V circuits from overload
  • 10 kA interrupting capacity stops heavy fault currents safely
  • Two-pole design handles single-phase loads on both hot legs
  • Plug-in mounting fits AQ and Power Mark Gold load centers
  • Toggle actuator gives clear on/off status at a glance

Specifications

BrandGE

Questions about this item

Will this 2-pole breaker fit a 3.3-inch tall panel slot?

Yes, the breaker is 3.3 inches long, 2 inches wide and 2.4 inches deep, so it matches standard THQL panel cut-outs.

Does the plug-in mounting require any tools to seat the breaker on the bus bar?

No tools are needed; align the two poles with the bus stabs and press firmly until the toggle sits flush with the panel face.

When should the breaker be replaced after a 10kA fault trip?

Replace it after any trip at or near the 10kA AIR rating, or if the toggle feels loose or shows discolouration.