We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

GE

GE THQL1130HID Circuit Breaker 30A 1 Pole 120/240V

SKU CH-QA02-RN37E

A high-intensity discharge circuit breaker rated 30 amps at 120/240 volts AC with a 10 kA interrupting rating for Power Mark Gold load centres

  • High-intensity discharge protection for lighting circuits
  • 30 A single-pole breaker rated 120/240 V AC
  • 10 kA interrupting rating at 120/240 V AC
  • Plug-in mounting fits Power Mark Gold and AQ panels
  • Screw-clamp terminals on a 100 A THQ frame

Circuit Breaker for HID Lighting Loads

The GE THQL1130HID is a 30A single-pole moulded-case breaker rated for 120/240V AC. It is built for high-intensity discharge lighting circuits and carries a 10kA interrupting rating at that voltage. The unit fits Power Mark Gold load centres and AQ lighting panels.

Plug-In Mounting for Compatible Panels

The breaker uses a plug-in mounting style with screw-clamp terminals for secure wire connection. It requires a panelboard from the AQ series or a Power Mark Gold load centre to install. The 100A frame size matches standard THQL enclosures, freeing adjacent spaces for other single-pole devices.

Toggle Actuation with 10kA Interrupting Capacity

A toggle actuator provides clear on/off indication during normal operation. The 10kA AIR rating at 120/240V AC handles fault currents on lighting branches. The breaker measures 6.5 inches in length and 3 inches in width for standard panel fit.

Highlights

  • High-intensity discharge protection for lighting circuits
  • 30 A single-pole breaker rated 120/240 V AC
  • 10 kA interrupting rating at 120/240 V AC
  • Plug-in mounting fits Power Mark Gold and AQ panels
  • Screw-clamp terminals on a 100 A THQ frame

Specifications

BrandGE

Questions about this item

How does the 10 kA interrupting rating hold up during a prolonged fault?

The breaker is rated to interrupt up to 10 kA at 120/240 V AC, so it will clear sustained over-currents within that limit without damage.

What heat or noise should I expect when the 30 A breaker runs continuously in a panel?

Normal operation produces only a faint mechanical click on switching; the molded case dissipates heat passively inside the enclosure with no fan or audible hum.

Which load-center series must I already have for this THQL plug-in breaker to fit?

It is listed for GE Power Mark Gold load centers and AQ lighting panels that accept the THQL 100 A frame size.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.