We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

GE

GE THQC2130WL Circuit Breaker 30A 2 Pole 120/240V AC

SKU CH-11NS-0ZE9T

A 30 A, two-pole miniature circuit breaker rated 120/240 V AC with 10 kA interrupting capacity, DIN-rail or surface mount, and UL listing for GE panelboards

  • 30 A protection for two-pole 120/240 V AC circuits
  • 10 kA interrupting rating stops heavy fault current
  • UL Listed for code-compliant panelboard installation
  • Surface or DIN-rail mount fits GE THQ frames
  • Lug terminals accept 14–8 AWG copper or 12–8 AWG aluminium

GE THQC 30 A 2-Pole Breaker

This GE THQC miniature circuit breaker provides 30 A overcurrent protection on a 120/240 V AC single-phase supply. It mounts on a surface or DIN rail and fits GE panelboards that accept the 100 A THQ frame. A toggle actuator gives clear on/off indication. The unit carries a UL listing and a 10 kA interrupting rating at rated voltage.

Electricians wiring GE load centres

The breaker suits contractors and maintenance teams adding or replacing a 30 A two-pole circuit in compatible GE equipment. Lug terminals accept copper wire from 14 AWG to 8 AWG or aluminium from 12 AWG to 8 AWG. Installers needing a DC-rated device or a different pole count should select another model.

10 kA interrupting capacity

The 10 kA AIR rating at 120/240 V AC is the key figure that determines whether this breaker can safely clear a fault in your panel. Verify that the available short-circuit current at the installation point does not exceed this value before fitting the device.

Highlights

  • 30 A protection for two-pole 120/240 V AC circuits
  • 10 kA interrupting rating stops heavy fault current
  • UL Listed for code-compliant panelboard installation
  • Surface or DIN-rail mount fits GE THQ frames
  • Lug terminals accept 14–8 AWG copper or 12–8 AWG aluminium

Specifications

BrandGE

Questions about this item

What interrupting rating does the THQC2130WL provide at 120/240V AC?

The breaker is rated for a maximum AIR of 10 kA at 120/240V AC, so it can safely interrupt fault currents up to that level on a compatible single-phase panel.

What panel space and mounting style does this two-pole unit require?

It occupies two poles in a GE panelboard, mounts on a surface or DIN rail, and measures 3.3 in long, 2 in wide and 2.4 in deep.

How do I connect the conductors to the lug terminals, and what wire range is allowed?

Strip copper wire to 14–8 AWG or aluminium to 12–8 AWG, insert fully into the lug, and torque to the panelboard manufacturer’s specification to avoid loose connections.

Also in this aisle