We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

GE

GE THQB32060 Circuit Breaker 60A 3 Pole 240V AC 10kA

SKU CH-J8E8-HVSHK

A 60 A, three-pole bolt-on breaker rated 120/240 V AC with a 10 kA interrupting capacity for lighting panels and load centres

  • Three-pole protection for balanced three-phase loads
  • 60 A rating matches common branch-circuit sizing
  • 10 kA interrupting capacity clears faults safely
  • Bolt-on mounting fits compatible GE load centres
  • UL Listed for code-compliant installations

GE THQB 60 A Three-Pole Breaker

This GE THQB miniature circuit breaker provides 60 A over-current protection on a 120/240 V AC three-phase supply. It mounts by bolt-on in compatible load centres and lighting panels. The toggle actuator gives clear on/off indication. The breaker carries a 10 kA interrupting rating at the rated voltage.

10 kA Interrupting Limit

The 10 kA AIR rating is the maximum prospective fault current this device can safely interrupt at 120/240 V AC. Installations with higher available fault current require a breaker with a greater interrupting capacity. The standard frame size is 100 A, so the 60 A trip unit fits that frame without change.

Panel Compatibility And Wiring Check

Verify the load centre accepts THQB bolt-on breakers and has space for a three-pole unit. Confirm the panel bus rating suits a 60 A device. Use copper conductors between 8 AWG and 3 AWG with the lug terminals provided. The breaker is not rated for DC circuits.

Highlights

  • Three-pole protection for balanced three-phase loads
  • 60 A rating matches common branch-circuit sizing
  • 10 kA interrupting capacity clears faults safely
  • Bolt-on mounting fits compatible GE load centres
  • UL Listed for code-compliant installations

Specifications

BrandGE

Questions about this item

Should I choose the 60 A three-pole version or a different amperage for my panel?

Select the 60 A three-pole breaker when your circuit requires 60 A protection on a 120/240 V AC three-phase panel; other amperages protect different load levels.

What does the 10 kA interrupting rating mean once the breaker is installed?

It means the breaker can safely interrupt up to 10 000 amps of fault current at 120/240 V AC without damage.

Does the bolt-on mounting work with standard load-centre bus bars?

Yes, the bolt-on design fits GE load centres and lighting panels that accept THQB frame breakers.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.