We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

GE

GE TED136030WL Molded Case Circuit Breaker 30A 3 Pole 600V AC

SKU CH-F22G-C7E7V

A 30 A, three-pole molded-case breaker rated 600 V AC with 18 kA interrupting capacity, thermal-magnetic trip, and bolt-on mounting for GE panelboards

  • Thermal-magnetic trip protects circuits against overloads and short circuits
  • 30 A rating handles moderate three-phase loads up to 600 V AC
  • 18 kA interrupting capacity clears faults safely at common service voltages
  • Bolt-on mounting fits directly into compatible GE panelboards
  • Compact 6.31 × 4.13 × 4.09 in frame saves enclosure space

GE TED Series 30A Circuit Breaker

The GE TED136030WL is a moulded-case circuit breaker rated at 30 amps with a 600V AC voltage rating. It provides three-pole protection for commercial and industrial electrical panels. The unit uses thermal-magnetic trip technology with a fixed instantaneous setting. It mounts by bolting directly onto compatible GE panelboards.

Bolt-on Mounting and Lug Terminals

The bolt-on mounting style secures the breaker firmly to the panelboard bus, reducing resistance at the connection point. Line and load lug terminals accept conductors directly without separate accessories. This integrated terminal design simplifies installation and ensures reliable contact. The fixed instantaneous trip eliminates the need for field adjustment.

18kA Interrupting Rating at 480V AC

The breaker delivers an 18kA AIR rating at 120, 240, 277 and 480V AC, suitable for typical service-entrance and branch-circuit fault levels. It also carries DC ratings of 125, 250 and 500 volts for limited DC applications. The 150A frame size provides physical headroom within the TED series. It is not suited for systems requiring adjustable trip curves or higher interrupting capacities.

Highlights

  • Thermal-magnetic trip protects circuits against overloads and short circuits
  • 30 A rating handles moderate three-phase loads up to 600 V AC
  • 18 kA interrupting capacity clears faults safely at common service voltages
  • Bolt-on mounting fits directly into compatible GE panelboards
  • Compact 6.31 × 4.13 × 4.09 in frame saves enclosure space

Specifications

BrandGE

Questions about this item

Will the thermal-magnetic trip unit need periodic recalibration or replacement?

The thermal-magnetic trip is factory-set and not field-adjustable; the breaker is replaced as a unit if it no longer trips correctly.

What limits continuous operation at the 30 A rating?

The 150 A frame and bolt-on mounting in a GE panelboard determine the thermal envelope; sustained loads above 30 A will cause the thermal element to trip.

How much heat does the breaker dissipate when carrying full load all day?

At 30 A the molded-case design relies on convection through the panelboard enclosure; no forced-air cooling is required.