Fuji
Fuji VFC508P-2T Regenerative Blower 2.5 hp 79.7 in wc
Regenerative blower delivering 154 cfm flow at 79.7 in wc pressure and 70 in wc vacuum from a 2.5 hp motor running on 200-230V single-phase power
- Delivers strong airflow with 154 cfm maximum flow rate
- Handles demanding pressure tasks at 79.7 in wc maximum operating pressure
- Achieves deep vacuum levels reaching 70 in wc maximum vacuum
- Powered by a 2.5 hp motor for reliable performance
- Operates on standard 200-230V AC single-phase power
Application Scope
The Fuji VFC508P-2T is a single-phase regenerative blower rated at 2.5 hp for industrial air supply or vacuum duties. It delivers up to 154 cfm flow with a maximum pressure of 79.7 in wc and a maximum vacuum of 70 in wc. It suits process machinery, aeration systems and material handling where oil-free air is required.
Electrical and Pneumatic Limits
Operation requires a 200-230V AC supply at 60 Hz drawing 11.0 A; the motor will not run on 50 Hz or three-phase power. The 1 1/2 in female NPT inlet and outlet fix the piping size, so systems needing larger bore connections need adapters. Pressure and vacuum ceilings are fixed at the stated values and cannot be exceeded by speed changes.
Installation Notes
The aluminum housing keeps weight manageable for bolt-down mounting, but vibration isolation pads are recommended to prevent structure-borne noise. Wiring must be sized for the 11.0 A load with appropriate overload protection to avoid nuisance trips. The single NPT port gender on each side means installers must provide correct male-threaded fittings; mismatched threads are the most common cause of leaks.
Highlights
- Delivers strong airflow with 154 cfm maximum flow rate
- Handles demanding pressure tasks at 79.7 in wc maximum operating pressure
- Achieves deep vacuum levels reaching 70 in wc maximum vacuum
- Powered by a 2.5 hp motor for reliable performance
- Operates on standard 200-230V AC single-phase power
Specifications
| Brand | FUJI ELECTRIC |
|---|
Questions about this item
Should I pick the 2.5 hp single-phase version or look for a three-phase alternative?
This unit is a single-phase 2.5 hp blower running on 200-230V AC at 60 Hz, so choose it when only single-phase power is available.
What does the 79.7 in wc pressure rating mean for my application?
It can develop up to 79.7 in wc of pressure or 70 in wc of vacuum, delivering 154 cfm maximum flow at those levels.
Will the 1-1/2 in NPT female ports limit airflow in my piping?
Both inlet and outlet are 1-1/2 in NPT female; size your piping to match so the 154 cfm rating is not restricted.