We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Field Controls

Field Controls PVG-300 Power Venter 115V 310k BtuH

SKU CH-SB3S-ZAFEG

Vents gas furnaces, boilers and water heaters up to 310,000 BtuH on 115 V power

  • MaterialHAWA
  • ColorTransparent
  • Vents gas appliances up to 310,000 BtuH input
  • Operates on standard 115V AC household power
  • Replaces Tjernlund HS1, HST-1 and HSUL-1 models
  • Works with both natural gas and LP fuel types
  • Suitable for boilers, furnaces and water heaters

115 V Power Venter for Gas Appliances

The Field Controls PVG-300 is a 115 V AC power venter designed for furnaces, boilers and water heaters that burn LP or natural gas. It handles a maximum gas input of 310,000 BtuH and mounts directly to a 4 in vent pipe.

Installation uses a standard 4 in inlet and outlet

The unit connects to a 4 in vent pipe at both inlet and outlet. Wiring is 115 V AC. The housing is galvanized steel. No oil-fired ratings are provided, so the venter is not suited for oil appliances.

Rated for 310,000 BtuH gas input

The venter comfortably handles gas-fired equipment up to 310,000 BtuH with a 4 in vent. It does not carry an oil-fired rating, so oil boilers or furnaces fall outside its approved range.

Highlights

  • Vents gas appliances up to 310,000 BtuH input
  • Operates on standard 115V AC household power
  • Replaces Tjernlund HS1, HST-1 and HSUL-1 models
  • Works with both natural gas and LP fuel types
  • Suitable for boilers, furnaces and water heaters

Specifications

BrandFIELD CONTROLS
MaterialHAWA
ColorTransparent

Questions about this item

How can I confirm the PVG-300 is venting correctly after installation?

Verify the motor runs smoothly at 115V AC and that exhaust flows freely through the 4 in vent pipe; the unit is rated for gas appliances up to 310,000 BtuH input.

What comes with the PVG-300 and what must I supply separately?

The power venter unit is included; you must provide 4 in vent pipe, electrical wiring for 115V AC, and any mounting hardware required for your boiler, furnace or water heater.

Which version of the Field Controls power venter matches a 310,000 BtuH gas system?

The PVG-300 model is specified for natural gas or LP appliances with a maximum input of 310,000 BtuH and a 4 in vent diameter.