We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Field Controls

Field Controls GVD-8PL 24V Automatic Vent Damper Stainless Steel

SKU CH-JF8X-QZP1A

Automatic 24 VAC vent damper opens and closes in 15 seconds, preventing heat loss and cold-air infiltration while dual safety switches ensure burner fires only when fully open

  • Automatic vent damper opens and closes in 15 seconds
  • Dual safety switches ensure burner fires only when damper is fully open
  • Stainless steel construction provides superior corrosion resistance
  • Keyed wiring harness connector prevents incorrect wiring connections
  • Hold open switch allows manual damper positioning for troubleshooting

Automatic Gas Vent Damper

The Field Controls GVD-8PL is a 24 VAC automatic vent damper designed for gas heating systems. It opens to permit natural draft during appliance operation and closes to stop residual heat and conditioned air from escaping during off cycles. Stainless steel construction provides corrosion resistance for long service life.

Integration Requirements

The damper operates with 24 VAC, 60 Hz intermittent or standing pilot ignition systems and installs in the vent connector. A separate GVD-UWK wiring harness is required and connects via a keyed plug that prevents incorrect wiring. Dual safety switches allow the burner to fire only when the damper is fully open.

Thermal and Electrical Behaviour

The motor draws power only while moving, opening or closing in 15 seconds, and rests with power off at the motor. A hold-open switch lets technicians lock the damper open for appliance troubleshooting. The stainless steel body withstands flue-gas temperatures without warping or corrosion.

Highlights

  • Automatic vent damper opens and closes in 15 seconds
  • Dual safety switches ensure burner fires only when damper is fully open
  • Stainless steel construction provides superior corrosion resistance
  • Keyed wiring harness connector prevents incorrect wiring connections
  • Hold open switch allows manual damper positioning for troubleshooting

Specifications

BrandFIELD CONTROLS

Questions about this item

What is the opening and closing cycle time for the damper motor?

The damper opens in 15 seconds and closes in 15 seconds; power is off at the motor when at rest.

How much power does the 24 VAC motor draw during continuous daily operation?

The unit operates on 24 VAC, 60 Hz power; the motor only draws current during the 15-second open or close cycles and is unpowered at rest.

Which separate wiring harness kit is required to connect this damper?

The GVD-UWK wiring harness kit is required and sold separately; the damper includes a keyed connector plug that installs only one way.