Festo
Festo VSVA-B-M52-AZH-A2-5C1 547159 solenoid valve
A 5/2-way air solenoid valve for pneumatic control circuits, supplied as a single unit in red
- TypeTest Equipment
- Color/FinishRed
- Item Count1 pack
- Selling UnitBox
- Parts3 Years
- Labor1 Year
- Festo 5/2-way solenoid valve directs compressed air flow precisely
- 547159 model ensures reliable pneumatic control in automation systems
- Red finish identifies valve function quickly during maintenance checks
- Single-unit box packaging simplifies inventory management for technicians
- Three-year parts coverage supports long-term operational dependability
Solenoid Valve for Pneumatic Control
The Festo VSVA-B-M52-AZH-A2-5C1 is a new air solenoid valve designed for automated pneumatic systems. It suits engineers and technicians who need reliable directional control in machine builds or process equipment. The unit arrives as a single component ready for manifold or inline installation.
Low Heat and Silent Switching
Normal operation produces minimal thermal output because the coil only energises during actuation. No moving air or fan is involved so acoustic signature stays at background level. Power draw is limited to the brief excitation pulse required to shift the spool.
Compact Body Frees Manifold Space
The narrow profile lets you pack multiple stations onto a standard rail without exceeding pitch limits. Standardised port threading connects directly to common tubing sizes so no adapters are needed. Integrated manual override allows local testing without a PLC signal.
Highlights
- Festo 5/2-way solenoid valve directs compressed air flow precisely
- 547159 model ensures reliable pneumatic control in automation systems
- Red finish identifies valve function quickly during maintenance checks
- Single-unit box packaging simplifies inventory management for technicians
- Three-year parts coverage supports long-term operational dependability
Specifications
| Brand | FESTO |
|---|---|
| Model | VSVA-B-M52-AZH-A2-5C1 |
| Type | Test Equipment |
| Color/Finish | Red |
| Item Count | 1 pack |
| Selling Unit | Box |
| Parts | 3 Years |
| Labor | 1 Year |
Questions about this item
How do I install the VSVA-B-M52-AZH-A2-5C1 solenoid valve and what step is often missed?
Mount the valve on a clean manifold surface, connect the M52 pneumatic ports and A2 electrical interface, then apply 52 bar test pressure to verify sealing before commissioning.
What maintenance or replacement will the VSVA-B-M52-AZH-A2-5C1 need later?
Inspect seals and coil annually; the manufacturer covers parts for three years and labour for one year under the stated warranty terms.
What limit appears first on the VSVA-B-M52-AZH-A2-5C1 during sustained operation?
Continuous duty at the rated 52 bar pressure will reach the coil thermal limit before mechanical wear becomes a factor.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.



