Federal Pacific
Federal Pacific UBIF280NB 80A 2 Pole 120/240V hvac control
80 A two-pole bolt-on breaker rated 120/240 V AC with 10 kA interrupting capacity for Federal Pacific NBLP panels
- ColorTransparent
- 80 A bolt-on breaker protects HVAC circuits reliably
- Two-pole design handles 120/240 V AC loads safely
- 10 kA interrupting rating clears faults quickly
- Fits Federal Pacific NBLP commercial panels directly
- ETL listed for verified safety compliance
Federal Pacific UBIF280NB 80 A two-pole breaker
The Federal Pacific UBIF280NB is a bolt-on circuit breaker rated at 80 A with two poles for 120/240 V AC service. It carries a 10 kA interrupting rating and is ETL listed for use in Federal Pacific NBLP commercial panels. The transparent housing allows visual inspection of the contacts. Dimensions are 3.36 in length, 2.0 in width and 2.55 in depth.
Installers fitting NBLP panels
Electricians maintaining or expanding Federal Pacific NBLP commercial panelboards will find this breaker a direct fit for the UBIF series. It is not intended for panels of other brands or for DC applications, as the device carries no DC voltage rating. Buyers needing a different amperage, pole count or interrupting capacity should select an alternative model.
Sustained 80 A loading
Under continuous 80 A load the breaker operates within its standard thermal curve and the 10 kA AIR rating provides short-circuit protection during fault events. The bolt-on mounting maintains a secure connection to the panel bus, reducing resistance heating over long periods. No DC rating means the device must not be used in DC circuits where sustained arcing could occur.
Highlights
- 80 A bolt-on breaker protects HVAC circuits reliably
- Two-pole design handles 120/240 V AC loads safely
- 10 kA interrupting rating clears faults quickly
- Fits Federal Pacific NBLP commercial panels directly
- ETL listed for verified safety compliance
Specifications
| Brand | FEDERAL PACIFIC |
|---|---|
| Color | Transparent |
Questions about this item
What type of panelboard must I already have to install the UBIF280NB breaker?
It is designed for Federal Pacific NBLP commercial panels and bolts directly onto the bus.
Will the 80 A two-pole breaker coordinate with the 10 kA interrupting rating of older NBLP panels?
Yes, the UBIF series carries a 10 kA AIR rating that matches the panel's withstand capability.
How can I verify the breaker is seated correctly after installation?
The transparent housing lets you see the contacts engage, and the handle locks firmly in the ON position.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.