Federal Pacific
Federal Pacific UBIF215N 2-Pole 15 A Circuit Breaker
Two-pole 15 A miniature breaker rated 120/240 V AC with 10 kA interrupting capacity, plug-in mounting for Federal Pacific load centres
- 15 A standard breaker protects 120/240 V circuits
- 10 kA interrupt rating clears short-circuit faults safely
- Plug-in mounting fits Federal Pacific X125-0816C load centres
- Two-pole design controls both legs of single-phase supply
- Compact 3.4 in frame installs in tight panel spaces
Federal Pacific UBIF215N Two-Pole Breaker
This Federal Pacific UBIF215N is a two-pole miniature circuit breaker rated at 15 amps for 120/240 volt AC single-phase systems. It uses a plug-in mounting style and a toggle actuator, designed specifically for compatible Federal Pacific load centers such as the X125-0816C series.
Sustained Load Behaviour
The breaker carries a maximum AIR rating of 10kA at 120/240V AC within a 70A frame size, indicating its capacity to interrupt fault currents safely. It is not rated for DC voltage, so it must remain on AC circuits only. Operating temperature minimum is 0 degrees Fahrenheit.
Installation Notes
Plug-in mounting simplifies insertion into the correct panelboard bus, and the terminal connection uses a lug for secure conductor attachment. The unit measures 3.4 inches in length, 2 inches in width and 2.6 inches in depth. Verify the load center series matches X125-0816C before installation to avoid fitment issues.
Highlights
- 15 A standard breaker protects 120/240 V circuits
- 10 kA interrupt rating clears short-circuit faults safely
- Plug-in mounting fits Federal Pacific X125-0816C load centres
- Two-pole design controls both legs of single-phase supply
- Compact 3.4 in frame installs in tight panel spaces
Specifications
| Brand | Federal Pacific |
|---|---|
| Model | UBIF215N |
Questions about this item
Does the 15 A breaker generate noticeable heat or noise when it runs continuously at full load?
The UBIF215N is a passive toggle device with no fan or moving parts beyond the switch mechanism, so it produces no audible noise and only minimal heat during normal 15 A operation.
Which panelboard series must I already have installed for this 2-pole breaker to plug in correctly?
The breaker is listed for Federal Pacific load centers in the X125-0816C series; it uses a plug-in mounting style that fits that specific bus design.
Will this 10 kA breaker coordinate safely with older 70 A frame breakers already in the same panel?
The UBIF215N carries a 10 kA interrupting rating at 120/240 V AC and shares the 70 A frame size, so it can be used alongside existing 70 A frame devices in a compatible Federal Pacific panel.