Federal Pacific
Federal Pacific UBIF15NB HVAC Control, 15A 1 Pole 120V AC
A 15 A, single-pole bolt-on breaker rated 120 V AC with a 10 kA interrupting capacity for Federal Pacific NBLP panels
- ColorTransparent
- ETL Listed confirms safety compliance for panel use
- 10 kA interrupting rating handles high fault currents
- Bolt-on design secures directly to Federal Pacific NBLP panels
- 15 A single-pole rating protects 120 V AC circuits
- Compact 3.36 in length fits standard panel spaces
Federal Pacific UBIF15NB Breaker
The Federal Pacific UBIF15NB is a bolt-on circuit breaker rated at 15 A and 120 V AC. It is designed for single-pole protection in Federal Pacific NBLP commercial panels. This new component suits electricians and facility managers maintaining compatible load centres.
10 kA Interrupting Rating
The breaker carries a maximum AIR rating of 10 kA, which determines its ability to interrupt fault current safely. This figure is the primary specification that confirms suitability for a given panel’s available short-circuit current. Panels requiring a higher interrupting capacity cannot use this device.
ETL Listed Standard Type
Built as a standard-type breaker with ETL listing, it meets recognised safety benchmarks for sustained operation. The transparent housing allows visual inspection of internal contacts during routine checks. Dimensions are 3.36 in length, 1.0 in width and 2.55 in depth for panel fit verification.
Highlights
- ETL Listed confirms safety compliance for panel use
- 10 kA interrupting rating handles high fault currents
- Bolt-on design secures directly to Federal Pacific NBLP panels
- 15 A single-pole rating protects 120 V AC circuits
- Compact 3.36 in length fits standard panel spaces
Specifications
| Brand | FEDERAL PACIFIC |
|---|---|
| Color | Transparent |
Questions about this item
What does the 15 A rating mean for my panel circuit?
It means the breaker will carry up to 15 amps continuously and trip if the load exceeds that value, protecting the wiring on a 120 V AC branch circuit.
How does the bolt-on design limit the panels it can be installed in?
The bolt-on mounting fits only Federal Pacific NBLP commercial panels; it cannot be used in plug-on or other manufacturers' load centres.
What are the exact dimensions I need to clear for this breaker?
The unit measures 3.36 in long, 1.0 in wide and 2.55 in deep, so allow at least that much space inside the panel enclosure.