Federal Pacific
Federal Pacific UBIF050N 50A 1 Pole Miniature Circuit Breaker
Single-pole miniature circuit breaker rated 50 A at 120 V AC with a 10 kA interrupting capacity, plug-in mounting and a toggle actuator for Federal Pacific load centres
- Rated 50 A for reliable single-phase protection
- 10 kA interrupting capacity handles high fault currents
- Plug-in mounting fits Federal Pacific X125-0816C load centres
- Compact 3.4 in length saves panel space
- Operates from 0 °F in cold environments
Federal Pacific UBIF050N 50A Breaker
This single-pole miniature circuit breaker rated at 50 amps protects 120V AC branch circuits in compatible Federal Pacific load centres. It is intended for electricians and facility managers who need a plug-in replacement for standard UBIF-series panels. The toggle actuator provides clear on-off indication during maintenance.
120V AC Standard Interface Limits
The breaker carries a 10kA interrupting rating at 120 volts AC and is not rated for DC applications. It fits only single-phase panels in the X125-0816C series using a plug-in mounting style with lug terminals. Installers must verify panel compatibility before fitting because the device will not seat in other load-centre families.
50 Amp Capacity With 60A Frame
A 60-amp frame size gives modest headroom above the 50-amp trip rating for short-duration inrush currents. The breaker handles typical lighting and receptacle loads but reaches its limit on continuous heavy-appliance circuits exceeding its nameplate value. Operation below zero degrees Fahrenheit is outside the specified temperature range.
Highlights
- Rated 50 A for reliable single-phase protection
- 10 kA interrupting capacity handles high fault currents
- Plug-in mounting fits Federal Pacific X125-0816C load centres
- Compact 3.4 in length saves panel space
- Operates from 0 °F in cold environments
Specifications
| Brand | FEDERAL PACIFIC |
|---|
Questions about this item
Which amperage and pole count should I select for a single-phase 120 V circuit?
This breaker is rated 50 A with one pole, matching a single-phase 120 V AC load centre.
What does the 10 kA AIR rating mean when the breaker is installed?
It can safely interrupt up to 10 000 amps of fault current at 120 V AC without damage.
How does the plug-in mounting and lug terminal limit the wire size I can use?
The plug-in design fits Federal Pacific load centres, and the lug terminal accepts conductors suited to the 60 A frame.