FASCO
FASCO A362 Blower 3000 RPM 115V 1 Phase 92 CFM
Rectangular OEM blower for furnace replacement, 3000 RPM, 115 V single-phase, 92 CFM airflow
- ColorTransparent
- Delivers 92 CFM airflow at zero static pressure
- Runs at 3000 RPM for consistent furnace circulation
- Operates on standard 115 V single-phase household power
- Draws only 1.6 A for efficient energy use
- Withstands inlet temperatures up to 400 °F
FASCO A362 Blower for Furnace Replacement
The FASCO A362 is a direct-drive OEM blower designed to replace Trane model 7002-3273 in furnace applications. It operates on 115V AC single-phase power with a shaded-pole motor rated for 1.6 amps at 60 Hz. Wire leads provide the electrical connection for straightforward installation. The unit is built for continuous duty in heating systems.
3000 RPM Shaded-Pole Motor Speed
The motor runs at a fixed maximum speed of 3000 RPM with a single-speed configuration. This determines the airflow delivery and static pressure capability for the furnace system. The shaded-pole design offers simple, reliable operation without capacitor requirements. Motor insulation Class B supports the rated operating temperatures.
92 CFM Airflow at Zero Static Pressure
At 0.000 in wc static pressure the blower delivers 92 cfm, with a maximum static pressure rating of 2 in wc. It handles inlet air temperatures up to 400 degrees F through a 5-inch inlet diameter. Airflow decreases as system static pressure rises toward the 2 in wc limit. The transparent housing allows visual inspection of the blower wheel during operation.
Highlights
- Delivers 92 CFM airflow at zero static pressure
- Runs at 3000 RPM for consistent furnace circulation
- Operates on standard 115 V single-phase household power
- Draws only 1.6 A for efficient energy use
- Withstands inlet temperatures up to 400 °F
Specifications
| Brand | FASCO |
|---|---|
| Color | Transparent |
Questions about this item
How much airflow does the 92 CFM rating deliver when installed in a furnace?
At zero static pressure the blower moves 92 cubic feet per minute of air; actual flow will drop as duct resistance increases.
What does the 115 V AC, 60 Hz, single-phase rating mean for wiring?
The motor runs on standard 115-volt household current at 60 hertz and draws 1.6 amps through wire leads.
Will the 5-inch inlet fit my existing furnace opening?
The blower has a 5-inch inlet diameter designed to match the Trane 7002-3273 and D341663P05 mounting pattern.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.