FASCO
FASCO A206 Blower 3000 RPM 115V 1 Phase 1.5A
OEM rectangular blower for Lennox furnaces runs at 3000 RPM on 115 V single-phase power drawing 1.5 A with shaded-pole motor rated for 400 °F inlet air
- ColorTransparent
- OEM replacement for Lennox furnaces using model 65204100
- Direct-drive shaded-pole motor runs at 3000 RPM for strong airflow
- 115 V single-phase operation draws only 1.5 A
- Class B insulation tolerates inlet air up to 400 °F
- Delivers up to 2 1/8 in wc static pressure for ducted systems
HVAC Blower for Furnace Replacement
The FASCO A206 is a direct-drive blower designed as an OEM replacement for compatible Lennox furnace models. It operates on a standard 115V AC single-phase supply at 60 Hz, drawing 1.5 A through wire leads. The shaded-pole motor runs at a fixed 3000 RPM with a single speed setting. This unit suits technicians or building managers needing a direct swap for the listed part numbers.
Shaded-Pole Motor Thermals and Noise
The motor carries a Class B insulation rating and accepts inlet air temperatures up to 400 degrees F, allowing operation in hot furnace environments. As a shaded-pole design running at 3000 RPM, it produces typical single-speed motor sound levels without variable-speed control. Power draw remains steady at the nameplate 1.5 A during normal operation. The 2 1/8 in wc maximum static pressure rating defines its airflow capability against duct resistance.
Steel Housing with 5 Inch Inlet
The blower features a steel housing with a 5 in inlet diameter and wire-lead electrical connections for direct wiring. It replaces Lennox manufacturer model numbers 65204100, 20J8901, 7021-8473 and 7021-8983. The transparent colour indicates the housing finish supplied. Build quality targets OEM durability standards for furnace integration. Buyers needing a different inlet size, dual-voltage wiring or a multi-speed motor cannot use this unit.
Highlights
- OEM replacement for Lennox furnaces using model 65204100
- Direct-drive shaded-pole motor runs at 3000 RPM for strong airflow
- 115 V single-phase operation draws only 1.5 A
- Class B insulation tolerates inlet air up to 400 °F
- Delivers up to 2 1/8 in wc static pressure for ducted systems
Specifications
| Brand | FASCO |
|---|---|
| Color | Transparent |
Questions about this item
How is the FASCO A206 blower installed and what wiring step do people miss?
Mount the blower in the furnace housing using the 5 inch inlet diameter and connect the wire leads to a 115V AC, 1 phase, 60 Hz supply rated for 1.5 A; the step often missed is confirming the motor insulation Class B rating matches the circuit protection.
What maintenance or replacement will the FASCO A206 blower need later?
The shaded pole motor runs at 3000 RPM with Class B insulation and a 400 °F maximum inlet air temperature; plan to inspect the bearings and clean the impeller annually, and replace the blower if vibration or reduced airflow appears.
What limit shows up first under sustained use on the FASCO A206 blower?
The maximum static pressure of 2 1/8 in wc and the 400 °F inlet air temperature limit are the first constraints reached during continuous operation; exceeding either will trip thermal protection or reduce airflow.