Fans S4D500-AM03-01 EBM axial flow condenser fan 400V 3-phase
Three-phase axial condenser fan runs at 400 V with CE approval and thermal overload protection
- Three-phase 400 V motor delivers 1390 rpm at 50 Hz
- 720 W power draw at 50 Hz keeps energy costs low
- Thermal overload protector guards motor during phase failure
- Braided steel blades with black coating resist corrosion in harsh environments
- Operates from -40 °C to +65 °C for cold-store and hot-climate use
Industrial axial fan for 400 V three-phase systems
This EBM axial flow condenser fan operates on three-phase 400 VAC supplies at 50 Hz or 60 Hz. It delivers 1390 rpm at 50 Hz and 1590 rpm at 60 Hz with power draw of 720 W and 1020 W respectively. The integrated motor design suits cold storage and HVAC installations where space is limited.
Suits plants needing CE-approved condenser airflow
Facilities that require impedance-protected motors with thermal overload protection and a minimum ambient rating of -40 °C will find this unit compatible. Sites without three-phase 400 V infrastructure or that need variable-speed control beyond the fixed 50/60 Hz ratings should consider other solutions.
Sustained operation at up to 65 °C ambient
At 50 Hz the fan runs continuously at 1390 rpm drawing 1.41 A while developing 140 Pa back pressure. At 60 Hz it holds 1590 rpm at 1.7 A with 130 Pa pressure. Thermal overload protectors guard the motor during prolonged duty or phase-failure events.
Highlights
- Three-phase 400 V motor delivers 1390 rpm at 50 Hz
- 720 W power draw at 50 Hz keeps energy costs low
- Thermal overload protector guards motor during phase failure
- Braided steel blades with black coating resist corrosion in harsh environments
- Operates from -40 °C to +65 °C for cold-store and hot-climate use
Specifications
No published specifications for this item yet.
Questions about this item
What three-phase supply voltage is required to run the S4D500-AM03-01 fan?
The fan is rated for 400 VAC three-phase at 50 Hz and 460 VAC three-phase at 60 Hz.
Will the fan operate reliably at the same ambient temperatures as my existing 50 °C-rated equipment?
Yes, it is rated for continuous operation up to 65 °C at 50 Hz and 60 °C at 60 Hz, exceeding a 50 °C design limit.
What current reading confirms the fan is running normally at 50 Hz on a 400 V supply?
A steady current draw of 1.41 A per phase indicates correct operation under nominal conditions.