ETCR
ETCR ETCR8600 Leakage Protector Tester 500mA 0-999ms
Tests leakage protector trip current up to 500 mA and operating time up to 999 ms with ten selectable current steps and a backlit display
- TypeTest Equipment
- Color/FinishRed
- Item Count1 pack
- Selling UnitBox
- Parts3 Years
- Labor1 Year
- Tests leakage initiating current up to 500mA for comprehensive protector verification
- Measures operating time from 0 to 999ms with high accuracy
- Offers 10 selectable test currents from 15mA to 500mA for flexible testing
- Includes both manual and automatic test modes for simple operation
- Features backlit large screen display for clear visibility in dark environments
Leakage protector tester for electricians
The ETCR8600 is a dedicated leakage protector tester designed for electricians who need to verify residual-current devices on site. It measures initiating current from 0 to 500mA and operating time from 0 to 999ms, covering the common trip-current grades of 15, 30, 50, 75, 100, 150, 200, 250, 300 and 500mA. Results appear on a large backlit screen that remains readable in low-light conditions. The unit fits in one hand and suits both indoor and field work.
Check your supply voltage and trip-grade range
Before ordering, confirm that the circuits you will test operate at or below 250V line voltage, as the tester is rated for supplies below that level. Verify that the leakage protectors you service use trip-current values within the ten fixed grades the instrument provides; devices calibrated to other values cannot be assessed with this model. Ensure you have access to the protected circuit’s test terminals and that local regulations permit live testing with a handheld instrument.
Handheld tool that needs no external power supply
The tester runs from its internal supply, so no mains lead or separate battery pack is required during measurements. Its manual and automatic test modes let you choose between single-step verification and a continuous sequence, freeing you from repeated button presses on repetitive jobs. The compact red enclosure fits in a standard tool bag, leaving bench space clear for other instruments. Because the device only tests leakage parameters, you will still need a separate multimeter or insulation tester for voltage, continuity or resistance checks.
Highlights
- Tests leakage initiating current up to 500mA for comprehensive protector verification
- Measures operating time from 0 to 999ms with high accuracy
- Offers 10 selectable test currents from 15mA to 500mA for flexible testing
- Includes both manual and automatic test modes for simple operation
- Features backlit large screen display for clear visibility in dark environments
Specifications
| Brand | ETCR |
|---|---|
| Model | ETCR8600 |
| Type | Test Equipment |
| Color/Finish | Red |
| Item Count | 1 pack |
| Selling Unit | Box |
| Parts | 3 Years |
| Labor | 1 Year |
Questions about this item
What comes in the box with the ETCR8600 and do I need to buy test leads separately?
The ETCR8600 ships as a single unit in one box; the supplier facts list no extra test leads or accessories, so nothing additional is mentioned as required.
Which current test grades does the ETCR8600 offer and how do I pick the right one?
The tester provides ten fixed current grades — 15, 30, 50, 75, 100, 150, 200, 250, 300 and 500 mA — select the grade that matches the rated trip current of the leakage protector you are checking.
What does the 0–999 ms operating-time range mean when I test a real protector?
It shows the exact trip time up to 999 ms; if the device under test trips within that window the reading is displayed directly, and the backlit screen makes the result readable in low light.