Emerson Climate Technologies
Emerson Climate Technologies White-Rodgers 36J24-614 Gas Valve 24 V 2.5 to 5.0" WC 7.0
Controls natural-gas or propane flow at 24 V with a 2.5 to 5.0" WC outlet range and 140 000 BtuH capacity
- Precise gas control with 2.5 to 5.0" WC regulation
- Reliable ignition powered by 24 V 0.3 A current
- Versatile fuel compatibility for natural gas and liquid propane
- High heating capacity up to 140,000 BtuH output
- Complete installation kit includes pressure regulator and conversion kit
White-Rodgers 36J24-614 Gas Valve
The White-Rodgers 36J24-614 is a new electronic gas valve designed for HVAC systems operating on natural gas or liquid propane. It runs on 24 V and includes a pressure regulator, conversion kit and on/off switch. The unit is not suited for installations that require an integrated pilot generator.
140,000 BtuH Heating Capacity
The maximum heating capacity of 140,000 BtuH is the primary figure that determines whether this valve matches the furnace or boiler it will control. The adjustable outlet pressure range of 2.5 to 5.0 inches WC and a 7.0 setting provide the fine tuning needed for proper combustion. Selecting a valve with a lower capacity would starve the appliance of fuel.
Sustained Load Behaviour
Under continuous firing the valve maintains the regulated outlet pressure across the 2.5 to 5.0 inches WC range without drift. The 0.3 A current draw remains stable during extended cycles and the quick-connect terminals resist loosening from thermal cycling. The 90-degree flow path and included inlet and outlet pressure taps allow straightforward monitoring while the system runs.
Highlights
- Precise gas control with 2.5 to 5.0" WC regulation
- Reliable ignition powered by 24 V 0.3 A current
- Versatile fuel compatibility for natural gas and liquid propane
- High heating capacity up to 140,000 BtuH output
- Complete installation kit includes pressure regulator and conversion kit
Specifications
| Brand | WHITE-RODGERS |
|---|
Questions about this item
What does the 140,000 BtuH heating capacity mean for my furnace?
It is the maximum input the valve can deliver to the burner, so the furnace must be rated at or below that figure.
How does the quick-connect terminal interface affect installation?
The 0.3 A, 24 V quick-connect terminals allow tool-free wiring to the ignition control.
What space is needed for the 90-degree flow direction and pressure taps?
The valve turns gas flow 90 degrees and includes inlet and outlet pressure taps, so allow clearance for the right-angle body and tap access.