We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Emerson Climate Technologies

Emerson Climate Technologies WHITE-RODGERS 36C03-433 Gas Valve NG/LP Standing Pilot 24 V 2.5 to 5.0 in

SKU CH-T1B2-FV548

Controls natural gas or liquid propane flow with a standing pilot, 24 V operation and 2.5 to 5.0 in pressure range

  • Dual-fuel ready with natural gas and propane compatibility
  • Standing-pilot operation provides reliable ignition without external power
  • Built-in pressure regulator simplifies installation and adjustment
  • 24 V control voltage suits standard residential HVAC systems
  • 280,000 Btu/h capacity handles large heating loads

WHITE-RODGERS 36C03-433 Gas Valve

This WHITE-RODGERS 36C03-433 gas valve controls natural gas or liquid propane flow in standing-pilot heating systems. It operates on a 24 V supply and draws 0.23 A. The straight-through flow body handles heating capacities up to 280,000 BtuH. It is not suited for buyers who need hot-surface or electronic ignition compatibility.

Installation requirements and common issues

The valve includes a pressure regulator, conversion kit, on/pilot/off switch, and inlet and outlet pressure taps with side taps. A pilot generator kit is not included and must be sourced separately. The 2.5 to 5.0 in dimension must match the existing piping layout. Miswiring the 24 V circuit or omitting the conversion kit for the target fuel are frequent errors.

Heating capacity limit

Maximum heating capacity is rated at 280,000 BtuH. Systems requiring a higher input will exceed this valve's flow rating. Verify the appliance nameplate against this figure before purchase.

Highlights

  • Dual-fuel ready with natural gas and propane compatibility
  • Standing-pilot operation provides reliable ignition without external power
  • Built-in pressure regulator simplifies installation and adjustment
  • 24 V control voltage suits standard residential HVAC systems
  • 280,000 Btu/h capacity handles large heating loads

Specifications

BrandWHITE-RODGERS

Questions about this item

How do I verify the 0.23 A current draw is correct after wiring the 24 V valve?

With power applied, measure the current on the 24 V supply leads using a multimeter set to AC amps; a reading near 0.23 A confirms the valve is operating within specification.

What components come with the 36C03-433 valve and what must be sourced separately?

The valve includes a pressure regulator, on/pilot/off switch, conversion kit, and inlet and outlet pressure taps; a pilot generator kit is not included and must be purchased separately.

Which version of the 36C03-433 should I select for a 280,000 BtuH natural-gas furnace with a 3 in water-column manifold?

This single model handles both natural gas and liquid propane, covers heating capacities up to 280,000 BtuH, and regulates outlet pressure from 2.5 to 5.0 in water column, so it suits the described application.

Also in this aisle