Emerson Climate Technologies
Emerson Climate Technologies 36H32-423 HVAC Control
Controls gas flow for natural gas or liquid propane heating systems up to 300,000 BtuH with direct spark or hot surface ignition and includes a conversion kit
- Direct spark ignition for reliable starts
- Works with natural gas or liquid propane
- 300,000 BtuH maximum heating capacity
- Quick-connect terminals simplify wiring
- Pressure regulator and inlet/outlet taps included
Gas Valve for LP and Natural Gas
The White-Rodgers 36H32-423 is a straight-thru gas valve designed for heating systems using liquid propane or natural gas. It operates with a current draw of .41 A and connects via quick connect terminals. A maximum heating capacity of 300, 000 BtuH supports residential and light commercial furnaces. The valve includes a pressure regulator, on/off switch and conversion kit for fuel flexibility.
Installers needing direct spark
This valve suits technicians servicing equipment that uses direct spark ignition or hot surface ignition. It is not for systems requiring a pilot generator kit, as that kit is not included. Buyers working on appliances that need a different flow configuration or electrical connection type should verify compatibility before purchase.
Heating capacity of 300, 000 BtuH
The rated maximum output determines whether this valve can meet the appliance demand. Match the furnace nameplate rating to this figure to confirm the part is correct for the installation.
Highlights
- Direct spark ignition for reliable starts
- Works with natural gas or liquid propane
- 300,000 BtuH maximum heating capacity
- Quick-connect terminals simplify wiring
- Pressure regulator and inlet/outlet taps included
Specifications
| Brand | WHITE-RODGERS |
|---|
Questions about this item
Will the 36H32-423 gas valve connect to my existing quick-connect wiring harness?
Yes, the valve uses quick-connect terminals for its electrical connections, matching standard harnesses used with direct-spark or hot-surface ignition systems.
How can I verify the valve is operating correctly after installation?
Measure the current draw; it should read approximately 0.41 A when the valve is energised, confirming the solenoid is functioning.
Does the 36H32-423 come with everything needed to switch between natural gas and propane?
The box includes a conversion kit and a pressure regulator; a pilot generator kit is not included and must be purchased separately if required.
Also in this aisle
People compared these