We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Eaton

Eaton 60A 3-pole 480VAC circuit breaker

SKU CH-ZDH1-GVFHA

Three-pole molded-case breaker rated 60 A at 480 VAC with thermal-magnetic trip and standard load-side lugs for reverse-feed applications

  • TypeCircuit Breakers
  • 60 A three-pole protection for 480 VAC systems
  • Thermal-magnetic trip responds to overloads and short circuits
  • Reverse-feed capability simplifies panel layout
  • Compact 4.13 in width fits standard enclosures

Eaton 60A 3-pole circuit breaker

This Eaton molded-case F-frame circuit breaker provides 60 amps of protection across three poles at 480VAC. It features a thermal-magnetic trip mechanism and standard load terminals that are suitable for reverse-feed applications. The unit measures 4.13 inches in width and uses a load-side lug connection.

Suits panels needing 60A three-phase protection

Electrical contractors wiring 480VAC three-phase panels will find the 60-amp rating and reverse-feed capability match standard commercial requirements. Installers who require a different amperage, pole count or voltage class should select an alternative breaker. Buyers needing integrated accessories or electronic trip units are not served by this thermal-magnetic model.

Highlights

  • 60 A three-pole protection for 480 VAC systems
  • Thermal-magnetic trip responds to overloads and short circuits
  • Reverse-feed capability simplifies panel layout
  • Compact 4.13 in width fits standard enclosures

Specifications

BrandEaton
TypeCircuit Breakers

Questions about this item

How do I install the Eaton 60A 3-pole breaker and which terminal orientation is commonly missed?

Mount the 4.13 in wide F-frame unit in a compatible panel, then connect supply conductors to the standard load terminals; the step often missed is verifying line versus load markings when using the reverse-feed capability.

What maintenance or replacement will the thermal-magnetic trip mechanism need over time?

The thermal-magnetic trip unit is sealed and not field-serviceable; plan to replace the entire 60A 480VAC breaker if nuisance tripping occurs or after a confirmed fault event.