Ductmate
Ductmate GRFDH10GA 10 in HVAC access door
Square 10-inch duct access door with fiberglass insulation, 24-gauge steel construction and a tab-in hinge rated to 175 °F
- ColorTransparent
- Square 10 in access door simplifies duct inspection
- Tab-In hinge allows quick tool-free installation
- 24 ga steel construction resists deformation under pressure
- Fiberglass insulation reduces thermal loss through the opening
- Rated to 175 °F for reliable performance in warm-air systems
Ductmate 10 Inch Access Door
The Ductmate GRFDH10GA is a square duct access door measuring 10 inches by 10 inches. It is designed for HVAC technicians and installers who need a secure inspection or service point in sheet-metal ductwork.
Sustained Load Behaviour
The door carries a maximum temperature rating of 175 degrees F, so it remains stable during continuous heating cycles. Its 24-gauge steel frame and 2 1/8 inch thick fiberglass insulation resist heat transfer and deformation over long operating periods.
Build Quality and Mounting
A tab-in hinge style allows the door to be inserted directly into a prepared duct opening without separate hinge hardware. The single cam latch secures the panel firmly, while 2-inch mounting studs provide a reliable anchor for the insulated assembly.
Highlights
- Square 10 in access door simplifies duct inspection
- Tab-In hinge allows quick tool-free installation
- 24 ga steel construction resists deformation under pressure
- Fiberglass insulation reduces thermal loss through the opening
- Rated to 175 °F for reliable performance in warm-air systems
Specifications
| Brand | DUCTMATE |
|---|---|
| Color | Transparent |
Questions about this item
Will the single-cam latch and 24-ga steel hold the door tight after daily temperature swings up to 175 °F?
The 24-ga steel frame and single-cam latch are rated for continuous service at 175 °F, so the door remains sealed through normal HVAC heat cycles.
What duct opening does the 10 × 10 in tab-in frame fit without extra framing?
The tab-in design slides into a 10-inch by 10-inch square cut-out in the duct wall; no separate mounting studs or additional framing are required.
Can the fibreglass-insulated panel sit next to older uninsulated duct sections without creating condensation?
The 2-1/8-inch thick fibreglass-insulated panel reduces surface-temperature differences, helping prevent condensation where it meets uninsulated ductwork.